EUVIMEDEUVIMED entdecken
Crossref

Early‐Stage Feasibility Testing of a Nutating Disc for Innovative Cardiovascular Applications

Gretel Monreal iD, Steven C Koenig, Joshua G Crane, Mark S Slaughter, David M Lancisi, Robert Mastromattei, Richard K Wampler

Artificial Organs · 2025

DOI: 10.1111/aor.70051 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Gretel Monreal und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky, USA. Hauptthemen laut MEDLINE: Heart, Artificial, Heart Failure, Heart-Assist Devices. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magvad LLC is developing an innovative total artificial heart (TAH) based on a single nutating (nonrotating, “wobbling”) disc pump design to provide up to 8 L/min pulsatile flow at 100 mmHg pressure in children and adults with end‐stage heart failure (HF). We present an early‐stage in vitro study to demonstrate proof‐of‐concept of a nutating disc mechanism for future cardiovascular applications.

Methods

A commercially available single nutating disc water meter (Recordall, Badger Meter 25–3/4″) was modified and connected to a motor via a shaft coupler and controlled via software to regulate disc “wobbles” per minute. The nutating disc pump was integrated into static and HF‐tuned dynamic mock loops and operated at shaft rotational speeds of 25–225 rpm.

Results

Pressure–flow ( H – Q ) curves demonstrated the pump generated 7 L/min flow at 100 mmHg (225 rpm). Pump flow, motor work, hemodynamic work, and pump efficiency increased with increasing wobble speed. The pump restored hemodynamics in the dynamic HF mock loop by increasing mean arterial flow and pressure, augmenting pulsatility, and decreasing venous pressure with increasing wobble speed.

Conclusions

These results demonstrate proof‐of‐concept and very early‐stage feasibility of a single nutating disc to function as a novel low‐speed volume displacement pulsatile flow mechanism for future cardiovascular applications including the development of an innovative TAH.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart, ArtificialHeart FailureHeart-Assist DevicesFeasibility StudiesHumansHemodynamicsPulsatile FlowProsthesis DesignProof of Concept Study

Stichwörter der Autor:innen

mechanical circulatory supportnutating discpumptotal artificial heartwobble

Autor:innen und Institutionen

  • Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky, USA.
  • Department of Bioengineering, University of Louisville, Louisville, Kentucky, USA.
  • Magvad LLC, Loomis, California, USA.

ORCID-Profile: Gretel Monreal

Zitieren

APA

Monreal, G., Koenig, S. C., Crane, J. G., Slaughter, M. S., Lancisi, D. M., Mastromattei, R., & Wampler, R. K. (2025). Early‐Stage Feasibility Testing of a Nutating Disc for Innovative Cardiovascular Applications. Artificial Organs. https://doi.org/10.1111/aor.70051

Vancouver

Monreal G, Koenig SC, Crane JG, Slaughter MS, Lancisi DM, Mastromattei R, et al. Early‐Stage Feasibility Testing of a Nutating Disc for Innovative Cardiovascular Applications. Artificial Organs. 2025. doi:10.1111/aor.70051

BibTeX
@article{Monreal2025,
  author = {Monreal, Gretel and Koenig, Steven C and Crane, Joshua G and Slaughter, Mark S and Lancisi, David M and Mastromattei, Robert and Wampler, Richard K},
  title = {Early‐Stage Feasibility Testing of a Nutating Disc for Innovative Cardiovascular Applications},
  journal = {Artificial Organs},
  year = {2025},
  doi = {10.1111/aor.70051}
}
Kostenlos starten →