Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments

Matthew Hirschhorn iD, Nicholas Catucci, Steven W Day iD, Randy M Stevens, Vakhtang Tchantchaleishvili iD, Amy L Throckmorton iD

Artificial Organs · 2023

DOI: 10.1111/aor.14480 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2023. Verfasst von Matthew Hirschhorn und 5 weiteren Autor:innen. Beteiligte Einrichtung: BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Heart-Assist Devices, Heart, Artificial. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The purpose of this research is to address ongoing device shortfalls for pediatric patients by developing a novel pediatric hybrid total artificial heart (TAH). The valveless magnetically‐levitated MCS device ( Dragon Heart ) has only two moving parts, integrates an axial and centrifugal blood pump into a single device, and will occupy a compact footprint within the chest for the pediatric patient population.

Methods

Prior work on the Dragon Heart focused on the development of pump designs to achieve hemodynamic requirements. The impeller of these pumps was shaft‐driven and thus could not be integrated for testing. The presented research leverages an existing magnetically levitated axial flow pump and focuses on centrifugal pump development. Using the axial pump diameter as a geometric constraint, a shaftless, magnetically supported centrifugal pump was designed for placement circumferentially around the axial pump domain. The new design process included the computational analysis of more than 50 potential centrifugal impeller geometries. The resulting centrifugal pump designs were prototyped and tested for levitation and no‐load rotation, followed by in vitro testing using a blood analog. To meet physiologic demands, target performance goals were pressure rises exceeding 90 mm Hg for flow rates of 1–5 L/min with operating speeds of less than 5000 RPM.

Results

Three puck‐shaped, channel impellers for the centrifugal blood pump were selected based on achieving performance and space requirements for magnetic integration. A quasi‐steady flow analysis revealed that the impeller rotational position led to a pulsatile component in the pressure generation. After prototyping, the centrifugal prototypes (3, 4, and 5 channeled designs) demonstrated levitation and no‐load rotation. Hydraulic experiments established pressure generation capabilities beyond target requirements. The pressure‐flow performance of the prototypes followed expected trends with a dependence on rotational speed. Pulsatile blood flow was observed without pump‐speed modulation due to rotating channel passage frequency.

Conclusion

The results are promising in the advancement of this pediatric TAH. The channeled impeller design creates pressure‐flow curves that are decoupled from the flow rate, a benefit that could reduce the required controller inputs and improve treatment of hypertensive patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHeart, ArtificialChildHumansMagnetsProsthesis DesignPulsatile FlowMagneticsEquipment Design

Stichwörter der Autor:innen

pediatric blood pumppediatric circulatory supportpediatric total artificial heartpediatric ventricular assist devicerotary blood pump

Autor:innen und Institutionen

  • BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
  • Drexel Machine Shop, Office of Research and Innovation, Drexel University, Philadelphia, Pennsylvania, USA.
  • Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, New York, USA.
  • Pediatrics, College of Medicine, St. Christopher's Hospital for Children, Drexel University, Philadelphia, Pennsylvania, USA.
  • Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA.

ORCID-Profile: Matthew Hirschhorn, Steven W Day, Vakhtang Tchantchaleishvili, Amy L Throckmorton

Förderung

  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Hirschhorn, M., Catucci, N., Day, S. W., Stevens, R. M., Tchantchaleishvili, V., & Throckmorton, A. L. (2023). Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments. Artificial Organs. https://doi.org/10.1111/aor.14480

Vancouver

Hirschhorn M, Catucci N, Day SW, Stevens RM, Tchantchaleishvili V, Throckmorton AL. Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments. Artificial Organs. 2023. doi:10.1111/aor.14480

BibTeX
@article{Hirschhorn2023,
  author = {Hirschhorn, Matthew and Catucci, Nicholas and Day, Steven W and Stevens, Randy M and Tchantchaleishvili, Vakhtang and Throckmorton, Amy L},
  title = {Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments},
  journal = {Artificial Organs},
  year = {2023},
  doi = {10.1111/aor.14480}
}
Kostenlos starten →