Characterization and Evaluation of Interferential Current Stimulation for Functional Electrical Stimulation
Artificial Organs · 2025
DOI: 10.1111/aor.15027 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Organs, 2025. Verfasst von Rodrigo Osorio und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Universidad de Concepción, Concepción, Chile. Hauptthemen laut MEDLINE: Median Nerve, Ulnar Nerve, Electric Stimulation Therapy, Electric Stimulation. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Agencia Nacional de Investigación y Desarrollo.
Abstract (Originalsprache)
Background
Interferential current stimulation (ICS) has long been employed in neuromodulation and physical therapy, yet its mechanisms and potential applications in functional electrical stimulation (FES) remain under‐explored. We present new data, including neural activation reported by muscle force measurement, to evaluate the potential advantages of ICS, such as selective targeting and reduced discomfort.
Methods
Experiments were conducted on human participants, focusing on ulnar and median nerve activation with stainless steel and commercial conductive hydrogel electrodes. Key parameters, including electrode configuration, frequency, current amplitude, and skin preparation, were investigated to test their effects on activation thresholds, force generation, and user comfort.
Results
Our results revealed that ICS can achieve proportional muscle force control, although its efficiency was lower than rectangular biphasic pulse stimulation. The application of moisturizing cream and gel significantly improved comfort and reduced activation thresholds, underscoring their importance in optimizing ICS protocols. However, ICS required higher electrical power and caused discomfort during burst initiation with all electrodes, presenting challenges for its practical use in FES. Furthermore, our findings indicated that ICS did not exclusively activate neural regions at the difference or “beat” frequency but also by the carrier frequency, challenging some prior assumptions in the literature.
Conclusion
These results highlight the need for further research and practical measurements of neural recruitment and muscle fatigue and into the mechanisms of nerve activation and neuromuscular junction transmission with stimulation via the skin surface. Innovations in electrode design, stimulation waveforms, and protocols are also needed to enhance the efficacy and comfort of ICS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Universidad de Concepción, Concepción, Chile.
- School of Sports and Exercise Science, Liverpool John Moores University, Liverpool, UK.
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK.
- Department of Electric and Electronic Engineering, Universidad del Bio Bío, Concepción, Chile.
- School of Engineering, University of Warwick, Coventry, UK.
ORCID-Profile: Rodrigo Osorio, Jack Edmondson
Förderung
- Agencia Nacional de Investigación y Desarrollo
Zitieren
APA
Osorio, R., Edmondson, J., Hall, S. M., Saavedra, F., Sáez, J., Poulton, A., FitzGerald, J., Aqueveque, P., Andrews, B., & Jarvis, J. (2025). Characterization and Evaluation of Interferential Current Stimulation for Functional Electrical Stimulation. Artificial Organs. https://doi.org/10.1111/aor.15027
Vancouver
Osorio R, Edmondson J, Hall SM, Saavedra F, Sáez J, Poulton A, et al. Characterization and Evaluation of Interferential Current Stimulation for Functional Electrical Stimulation. Artificial Organs. 2025. doi:10.1111/aor.15027
BibTeX
@article{Osorio2025,
author = {Osorio, Rodrigo and Edmondson, Jack and Hall, Siobhan Mackenzie and Saavedra, Francisco and Sáez, Javier and Poulton, Adrian and FitzGerald, James and Aqueveque, Pablo and Andrews, Brian and Jarvis, Jonathan},
title = {Characterization and Evaluation of Interferential Current Stimulation for Functional Electrical Stimulation},
journal = {Artificial Organs},
year = {2025},
doi = {10.1111/aor.15027}
}
EUVIMED