Journal article in Artificial Organs, 2025. Written by Rachel C Klosko and 4 co-authors. Institution: Department of Pharmacy Practice, Binghamton University School of Pharmacy and Pharmaceutical Sciences, Johnson City, New York, USA. Major MEDLINE topics: Heart-Assist Devices, Enoxaparin, Anticoagulants, Hemorrhage. 24 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: NCATS NIH HHS, National Center for Advancing Translational Sciences.
Abstract (original language)
Background
The objective of this study is to determine the incidence of major bleeding events in patients implanted with continuous flow left ventricular assist devices (CF‐LVADs) bridged with enoxaparin (LMWH) compared to intravenous unfractionated heparin (IV UFH) for a subtherapeutic INR on warfarin.
Methods
A single‐center, retrospective, cohort study was conducted including patients with CF‐LVADs implanted between January 1, 2012 and July 1, 2020 who received at least one inpatient dose or outpatient prescription for LMWH or IV UFH at least 60 days after CF‐LVAD implantation. The primary endpoint was the incidence of major bleeding.
Results
In total, 176 orders were screened and 90 orders in 62 unique patients were included. Major bleeding and thromboembolic events occurred in 1 (2.5%) versus 4 (10.0%) orders ( p = 0.36) and 3 (7.5%) versus 1 (2.5%) orders ( p = 0.62) in the LMWH and IV UFH groups, respectively. One patient had a fatal thromboembolic event in each group. More patients receiving IV UFH had minor bleeding events (10 [25.0%] vs. 3 [7.5%]; p = 0.03).
Conclusions
There was no difference between bleeding and thromboembolic events in patients implanted with CF‐LVADs prescribed LMWH or IV UFH for bridging of subtherapeutic INRs. Larger prospective randomized data are needed to validate these findings.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Pharmacy Practice, Binghamton University School of Pharmacy and Pharmaceutical Sciences, Johnson City, New York, USA.
- Division of Cardiac Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
- Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
- Center for Biostatistics, The Ohio State University, Columbus, Ohio, USA.
- US Clinical Development, Medical and Regulatory Affairs, Novonordisk, Rochester, Minnesota, USA.
ORCID profiles: Rachel C Klosko
Funding
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
Cite
APA
Klosko, R. C., Whitson, B., Lampert, B., McLaughlin, E., & Orzel, L. (2025). Safety of enoxaparin in patients implanted with continuous flow left ventricular assist devices. Artificial Organs. https://doi.org/10.1111/aor.14908
Vancouver
Klosko RC, Whitson B, Lampert B, McLaughlin E, Orzel L. Safety of enoxaparin in patients implanted with continuous flow left ventricular assist devices. Artificial Organs. 2025. doi:10.1111/aor.14908
BibTeX
@article{Klosko2025,
author = {Klosko, Rachel C and Whitson, Bryan and Lampert, Brent and McLaughlin, Eric and Orzel, Libby},
title = {Safety of enoxaparin in patients implanted with continuous flow left ventricular assist devices},
journal = {Artificial Organs},
year = {2025},
doi = {10.1111/aor.14908}
}
EUVIMED