Noninvasive finger plethysmography for continuous blood pressure monitoring in patients with left ventricular assist device
Artificial Organs · 2023-09 · 47 (9) · 1472-1478
DOI: 10.1111/aor.14560 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Organs, online erschienen am 16.05.2023. Verfasst von Christopher G Favilla und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Heart-Assist Devices. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, American Heart Association, Institute for Translational Medicine and Therapeutics.
Abstract (Originalsprache)
Background
Accurate blood pressure (BP) measurement remains challenging in patients with HeartMate 3™ left ventricular assist devices (HM3 LVADs). The Finapres® NOVA is a promising non‐invasive continuous BP monitor that uses the volume clamp method via a finger cuff, so here we aimed to validate the instrument in HM3 patients.
Methods
In a single‐center cohort, BP was monitored in 15 patients within 72 h following HM3 implantation. A radial artery catheter quantified arterial blood pressure (ABP), while the NOVA measured finger arterial pressure (fiAP) and reconstructed brachial artery pressure (reBAP). Waveforms were recorded for 10 min, and mean values were calculated in 15‐s intervals. Resuts fiAP and ABP were moderately correlated during both the first (ICC 0.61, p = 0.04) and final measurements (ICC 0.66, p = 0.03). reBAP and ABP were strongly correlated during both the first (ICC 0.81, p = 0.002) and final measurements (ICC 0.83, p = 0.001). Both NOVA‐derived values may underestimate low BP values while overestimating relatively high BP values. The reBAP was within 5 mm Hg of the ABP in 40% of patients (and within 10 mm Hg in 67%).
Conclusions
This pilot represents the first evidence in support of the Finapres® NOVA for non‐invasive BP measurement in select patients with HM3 LVADs. The instrument may provide useful data during BP medication adjustments or pump titration, but despite the correlation between the non‐invasive reBAP and invasive ABP, individual‐level inaccuracy may be clinically meaningful. Further investigation is needed to clarify these limitations and optimize accuracy before widespread adoption in this unique patient population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Cardiothoracic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Division of Cardiology, Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Christopher G Favilla
Förderung
- NINDS NIH HHS
- American Heart Association
- Institute for Translational Medicine and Therapeutics
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Favilla, C. G., Carter, S. C., Atluri, P., Reehal, N., & Genuardi, M. V. (2023). Noninvasive finger plethysmography for continuous blood pressure monitoring in patients with left ventricular assist device. Artificial Organs, 47(9), 1472-1478. https://doi.org/10.1111/aor.14560
Vancouver
Favilla CG, Carter SC, Atluri P, Reehal N, Genuardi MV. Noninvasive finger plethysmography for continuous blood pressure monitoring in patients with left ventricular assist device. Artificial Organs. 2023;47(9):1472-1478. doi:10.1111/aor.14560
BibTeX
@article{Favilla2023,
author = {Favilla, Christopher G and Carter, Sarah C and Atluri, Pavan and Reehal, Navpreet and Genuardi, Michael V},
title = {Noninvasive finger plethysmography for continuous blood pressure monitoring in patients with left ventricular assist device},
journal = {Artificial Organs},
year = {2023},
volume = {47},
number = {9},
pages = {1472--1478},
doi = {10.1111/aor.14560}
}
EUVIMED