Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2025. Verfasst von Fabian Müller-Graf und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Center Rostock, Schillingallee 35, 18057, Rostock, Germany…. Hauptthemen laut MEDLINE: Machine Learning, Electric Impedance, Tomography, Aorta. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Universitätsmedizin Rostock.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hypotension in perioperative and intensive care settings is a significant risk factor associated with complications such as myocardial infarction and kidney injury thereby increasing perioperative complications and mortality. Continuous blood pressure monitoring is essential, yet challenging due to the invasive nature of current methods. Non-invasive techniques like Electrical Impedance Tomography (EIT) have been explored but face challenges in accurate and consistent blood pressure estimation. A machine learning (ML) approach was used to predict aortic blood pressures from EIT voltage measurements in landrace pigs. A convolutional neural network (CNN) was trained on a dataset of 75 298 heartbeats, to predict systolic (SAP), mean (MAP), and diastolic arterial pressures (DAP) of individuals whose arterial pressures were unknown to the algorithm. The Intraclass Correlation Coefficient (3,1) with absolute agreement (ICC) was calculated and the concordance was estimated, comparing reference blood pressure measurements and ML-derived estimates. A risk classification was estimated for the calculated blood pressure as suggested by Saugel et al. 2018. The ML-model demonstrated moderate correlations with invasive blood pressure measurements (ICC for SAP of 0.530, for MAP of 0.563, and for DAP of 0.521.) with a low risk score for 75.8% of the SAP and 64.2% of MAP estimated blood pressures. ML-techniques using EIT-voltages showed promising preliminary results in non-invasive aortic blood pressure estimation. Despite limitations in the amount of available training data and the experimental setup, this study illustrates the potential of integrating ML in EIT signal processing for real-time, non-invasive blood pressure monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Machine LearningElectric ImpedanceTomographyAortaBlood Pressure DeterminationBlood PressureArterial PressureAnimalsSwineAlgorithmsNeural Networks, ComputerHeart RateHypotensionHumansMaleMonitoring, PhysiologicReproducibility of Results

Stichwörter der Autor:innen

Arterial and aortic blood pressureBlood pressureElectrical impedance tomographyHemodynamic monitoringMachine learning

Autor:innen und Institutionen

  • Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Center Rostock, Schillingallee 35, 18057, Rostock, Germany. fabian.mueller-graf@med.uni-rostock.de.
  • Rudolf-Zenker-Institute for Experimental Surgery, University Medical Center Rostock, Schillingallee 69a, 18057, Rostock, Germany. fabian.mueller-graf@med.uni-rostock.de.
  • Institute of Communications Engineering, University of Rostock, Albert-Einstein-Straße 26, 18059, Rostock, Germany.
  • Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Center Rostock, Schillingallee 35, 18057, Rostock, Germany.

ORCID-Profile: Fabian Müller-Graf, Jacob P Thönes

Förderung

  • Deutsche Forschungsgemeinschaft
  • Universitätsmedizin Rostock

Zitieren

APA

Müller-Graf, F., Thönes, J. P., Krukewitt, L., Frenkel, P., Richter, H., Spors, S., Kühn, V., Zitzmann, A. R., Boehm, S. H., & Reuter, D. A. (2025). Non-invasive estimation of beat-by-beat aortic blood pressures from electrical impedance tomography data processed by machine learning. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-025-01274-2

Vancouver

Müller-Graf F, Thönes JP, Krukewitt L, Frenkel P, Richter H, Spors S, et al. Non-invasive estimation of beat-by-beat aortic blood pressures from electrical impedance tomography data processed by machine learning. Journal of Clinical Monitoring and Computing. 2025. doi:10.1007/s10877-025-01274-2

BibTeX
@article{MllerGraf2025,
  author = {Müller-Graf, Fabian and Thönes, Jacob P and Krukewitt, Lisa and Frenkel, Paul and Richter, Henryk and Spors, Sascha and Kühn, Volker and Zitzmann, Amelie R and Boehm, Stephan H and Reuter, Daniel A},
  title = {Non-invasive estimation of beat-by-beat aortic blood pressures from electrical impedance tomography data processed by machine learning},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2025},
  doi = {10.1007/s10877-025-01274-2}
}