A comprehensive evaluation of hemodynamic energy production and circuit loss using four different ECMO arterial cannulae
Artificial Organs · 2023
DOI: 10.1111/aor.14523 ↗Kurz gefasst
Fachartikel in der Zeitschrift Artificial Organs, 2023. Verfasst von Silver Heinsar und 12 weiteren Autor:innen. Beteiligte Einrichtung: Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
Pulsatile‐flow veno‐arterial extracorporeal membrane oxygenation (V‐A ECMO) has shown encouraging results for microcirculation resuscitation and left ventricle unloading in patients with refractory cardiogenic shock. We aimed to comprehensively assess different V‐A ECMO parameters and their contribution to hemodynamic energy production and transfer through the device circuit.
Methods
We used the i‐cor® ECMO circuit, which composed of Deltastream DP3 diagonal pump and i‐cor® console (Xenios AG), the Hilite 7000 membrane oxygenator (Xenios AG), venous and arterial tubing and a 1 L soft venous pseudo‐patient reservoir. Four different arterial cannulae (Biomedicus 15 and 17 Fr, Maquet 15 and 17 Fr) were used. For each cannula, 192 different pulsatile modes were investigated by adjusting flow rate, systole/diastole ratio, pulsatile amplitudes and frequency, yielding 784 unique conditions. A dSpace data acquisition system was used to collect flow and pressure data.
Results
Increasing flow rates and pulsatile amplitudes were associated with significantly higher hemodynamic energy production (both p < 0.001), while no significant associations were seen while adjusting systole‐to‐diastole ratio ( p = 0.73) or pulsing frequency ( p = 0.99). Arterial cannula represents the highest resistance to hemodynamic energy transfer with 32%–59% of total hemodynamic energy generated being lost within, depending on pulsatile flow settings used.
Conclusions
Herein, we presented the first study to compare hemodynamic energy production with all pulsatile ECLS pump settings and their combinations and widely used yet previously unexamined four different arterial ECMO cannula. Only increased flow rate and amplitude increase hemodynamic energy production as single factors, whilst other factors are relevant when combined.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.
- Faculty of Medicine, University of Queensland, Brisbane, Queensland, Australia.
- Critical Care Research Group, St Andrews War Memorial Hospital, Brisbane, Queensland, Australia.
- Department of Intensive Care, North Estonia Medical Centre, Tallinn, Estonia.
- Statistics Unit, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia.
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.
ORCID-Profile: Silver Heinsar, E-Peng Seah, Sebastiano Maria Colombo, Andrew Haymet
Zitieren
APA
Heinsar, S., Bartnikowski, N., Hartel, G., Farah, S. M., Seah, E. P., Wu, E., Colombo, S. M., Semenzin, C., Haymet, A., Rätsep, I., Pauls, J., Fraser, J. F., & Suen, J. Y. (2023). A comprehensive evaluation of hemodynamic energy production and circuit loss using four different ECMO arterial cannulae. Artificial Organs. https://doi.org/10.1111/aor.14523
Vancouver
Heinsar S, Bartnikowski N, Hartel G, Farah SM, Seah EP, Wu E, et al. A comprehensive evaluation of hemodynamic energy production and circuit loss using four different ECMO arterial cannulae. Artificial Organs. 2023. doi:10.1111/aor.14523
BibTeX
@article{Heinsar2023,
author = {Heinsar, Silver and Bartnikowski, Nicole and Hartel, Gunter and Farah, Samia M and Seah, E-Peng and Wu, Eric and Colombo, Sebastiano Maria and Semenzin, Clayton and Haymet, Andrew and Rätsep, Indrek and Pauls, Jo and Fraser, John F and Suen, Jacky Y},
title = {A comprehensive evaluation of hemodynamic energy production and circuit loss using four different ECMO arterial cannulae},
journal = {Artificial Organs},
year = {2023},
doi = {10.1111/aor.14523}
}
EUVIMED