EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Assessment of novel sonographic and biochemical tools for spontaneous preterm birth prediction in asymptomatic twin pregnancies

Júlia Ponce iD, Teresa Cobo, Clara Murillo, Anna Gonce, Ana B Sánchez-García, Ana P Dantas, David Coronado iD, Francesca Crovetto, Laura Guirado, Judit Bruch, Eduard Gratacós, Montse Palacio and 1 more

Acta Obstetricia et Gynecologica Scandinavica · 2025

DOI: 10.1111/aogs.15118 ↗

At a glance

Journal article in Acta Obstetricia et Gynecologica Scandinavica, 2025. Written by Júlia Ponce and 12 co-authors. Institution: BCNatal-Fetal Medicine Research Center, Hospital Clínic and Hospital Sant Joan de Déu, Barcelona, Spain. Major MEDLINE topics: Premature Birth, Pregnancy, Twin, Ultrasonography, Prenatal, Cervix Uteri. Cited 5 times so far (Crossref); 45 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Contracte Clínic de Recerca Emili Letang-Josep Font.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Prematurity is a major global health issue. Twin pregnancies are a group at especially high risk of preterm birth. Sonographic mid‐trimester cervical length has limited accuracy in predicting preterm birth. This study aimed to evaluate the association between mid‐trimester sonographic markers of early cervical remodeling and cervical inflammatory biomarkers and fetal fibronectin, alone or in combination, as predictors of preterm birth before 34+0 weeks in asymptomatic twin pregnancies. Material and Methods Prospective cohort study, including uncomplicated dichorionic or monochorionic‐diamniotic twin pregnancies, recruited and assessed between 18+0 and 24+6 weeks, from a single tertiary referral center between 2020 and 2023. At inclusion, transvaginal ultrasound was performed to assess the following sonographic markers (cervical length, uterocervical angle, cervical consistency index, cervical texture) and an endocervical sample was obtained prior to ultrasound to quantify the following cervical inflammatory biomarkers (tumor necrosis factor alpha, interleukins 1b, 6, 8, 18, matrix metalloproteinase‐8 and 9) and fetal fibronectin. The diagnostic performance of those sonographic and biochemical markers independently associated with spontaneous preterm birth before 34 weeks was analyzed by receiver operating characteristic curves and assessed through sensitivity and specificity analysis for several cutoffs.

Results

Of the 172 women included, cervical length was shorter (36 mm vs. 40 mm; p = 0.025) and uterocervical angle was wider (137° vs. 120°; p = 0.004) in the preterm group. Cervical consistency index, cervical texture score, cervical inflammatory biomarkers, and fetal fibronectin were similar among the study groups. The area under the curve to predict spontaneous preterm birth before 34+0 weeks was 0.722 (95% CI 0.577 to 0.866) for cervical length, 0.789 (95% CI 0.683 to 0.895) for uterocervical angle, and 0.852 (95% CI 0.752 to 0.952) for a combination of both. Based on the receiver operating characteristics curve cutoff, sensitivity and specificity for cervical length ≤37 mm was 55.6% and 66.3%, for an uterocervical angle ≥135° was 77.8% and 76.1%, and for both criteria present 44.4% and 93.3%, respectively.

Conclusions

This finding of this study suggests that the combination of cervical length and uterocervical angle in mid‐trimester sonographic assessment may improve the prediction of preterm birth before 34 weeks in asymptomatic and uncomplicated twin pregnancies.

Subjects

MeSH terms (MEDLINE)

Premature BirthPregnancy, TwinUltrasonography, PrenatalCervix UteriHumansFemalePregnancyAdultProspective StudiesBiomarkersFibronectinsCervical Length MeasurementPregnancy Trimester, SecondPredictive Value of Tests

Author keywords

cervical inflammatory biomarkerscervical lengthearly cervical remodelingmultiple pregnancypreterm birth predictionspontaneous preterm birthtwin pregnancyuterocervical angle

Substances

BiomarkersFibronectins

Authors and institutions

  • BCNatal-Fetal Medicine Research Center, Hospital Clínic and Hospital Sant Joan de Déu, Barcelona, Spain.
  • Fundació de Recerca Clínic Barcelona-IDIBAPS, Universitat de Barcelona, Barcelona, Spain.
  • Department of Biomedical Sciences, School of Medicine and Health Sciences, Universitat de Barcelona, Barcelona, Spain.
  • Transmural Biotech S. L., Barcelona, Spain.
  • Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Spain.
  • Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin RD21/0012/0003, Instituto de Salud Carlos III, Madrid, Spain.

ORCID profiles: Júlia Ponce, David Coronado, Mar Bennasar

Funding

  • Contracte Clínic de Recerca Emili Letang-Josep Font

Cite

APA

Ponce, J., Cobo, T., Murillo, C., Gonce, A., Sánchez-García, A. B., Dantas, A. P., Coronado, D., Crovetto, F., Guirado, L., Bruch, J., Gratacós, E., Palacio, M., & Bennasar, M. (2025). Assessment of novel sonographic and biochemical tools for spontaneous preterm birth prediction in asymptomatic twin pregnancies. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.15118

Vancouver

Ponce J, Cobo T, Murillo C, Gonce A, Sánchez-García AB, Dantas AP, et al. Assessment of novel sonographic and biochemical tools for spontaneous preterm birth prediction in asymptomatic twin pregnancies. Acta Obstetricia et Gynecologica Scandinavica. 2025. doi:10.1111/aogs.15118

BibTeX
@article{Ponce2025,
  author = {Ponce, Júlia and Cobo, Teresa and Murillo, Clara and Gonce, Anna and Sánchez-García, Ana B and Dantas, Ana P and Coronado, David and Crovetto, Francesca and Guirado, Laura and Bruch, Judit and Gratacós, Eduard and Palacio, Montse and Bennasar, Mar},
  title = {Assessment of novel sonographic and biochemical tools for spontaneous preterm birth prediction in asymptomatic twin pregnancies},
  journal = {Acta Obstetricia et Gynecologica Scandinavica},
  year = {2025},
  doi = {10.1111/aogs.15118}
}
Start for free →