EUVIMEDScopri EUVIMED
Open access · CC BY-NC 4.0

Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation

Carla Héléna Sousa iD, Marion Mercier, Nathalie Rioux-Leclercq, Erwan Flecher, Claude Bendavid, David Val-Laillet, Juliette Ferrant iD, Sylvie Jaillard, Emma Loiseau, Julien Branchereau, Yanis Berkane, Krystel Nyangoh Timoh and 4 more

Acta Obstetricia et Gynecologica Scandinavica · 2025

DOI: 10.1111/aogs.15056 ↗

At a glance

Journal article in Acta Obstetricia et Gynecologica Scandinavica, 2025. Written by Carla Héléna Sousa and 15 co-authors. Institution: Department of Gynecology, Rennes University Hospital, Hôpital Sud, Rennes, France. Major MEDLINE topics: Uterus, Organ Preservation, Perfusion, Hypothermia, Induced. Cited 5 times so far (Crossref); 39 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Société de Chirurgie Gynécologie et Pelvienne & Gedeon Richter.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Introduction

Graft optimization is a necessity in order to develop uterus transplantation from brain‐dead donors, as a complement to living donors, as these grafts are rare and the last organs retrieved in multiple organ donation. The aim of this study was to assess the feasibility and interest of hypothermic machine perfusion (HMP) in uterus transplantation using a porcine model; secondary outcomes were the evaluation of the graft's tolerance to a prolonged cold ischaemia time and to find new biomarkers of uterus viability. Material and Methods Fifteen uterus allotransplantations were performed in a porcine model, after 18 h of cold ischaemia, divided in three groups: Static cold storage in a HTK solution, HMP (with the VitaSmart (™) machine Bridge to Life Ltd.) with a UW‐MP solution, and static cold storage in a UW solution. The main outcome was macroscopic: uterine arteries pulsatility, recoloration, and bleeding at the cut. Secondary outcomes were histological analyses (Zitkute and inflammation scores), caspase3 immunohistochemistry and plasmatic dosage of biomarkers.

Results

14/15 allotransplantations were performed according to the protocol and met the criteria of macroscopic vitality. Grafts treated with HMP (MP did not show significantly more tissue) damage than the recipient's uterus, contrary to grafts in static cold storage, independently of the solution used. This difference disappeared one and 3 h after uterus transplantation. Plasma dosages before and after uterus transplantation did not allow to identify a new biomarker of uterus viability.

Conclusions

HMP is feasible in a porcine model, without inflicting damage on the grafts during cold ischaemia time. Grafts exposed to HMP seemed to better endure reperfusion phenomena, but this advantage did not last over time.

Subjects

MeSH terms (MEDLINE)

UterusOrgan PreservationPerfusionHypothermia, InducedCold IschemiaAnimalsFemaleSwineOrgan Preservation SolutionsGraft SurvivalModels, AnimalAdenosineRaffinoseGlutathione

Author keywords

animal modelassisted reproductive technologieshypothermic machine perfusioninfertilityuterus transplantation

Substances

Organ Preservation SolutionsAdenosineRaffinoseGlutathione

Authors and institutions

  • Department of Gynecology, Rennes University Hospital, Hôpital Sud, Rennes, France.
  • Institute for Research in Health, Environment and Work (Irset), Rennes, France.
  • Department of Pathology, Rennes University Hospital, Hôpital Pontchaillou, France.
  • Department of Cardiothoracic and Vascular Surgery, Rennes University Hospital, Hôpital Pontchaillou, Rennes, France.
  • Laboratory of Biochemistry, Rennes University Hospital, Hôpital Pontchaillou, Rennes, France.
  • INRAE, INSERM, University Of Rennes, NuMeCan Institute, Nutrition Metabolisms And Cancer, Rennes, France.

ORCID profiles: Carla Héléna Sousa, Juliette Ferrant, Isis Carton

Funding

  • Société de Chirurgie Gynécologie et Pelvienne & Gedeon Richter

Cite

APA

Sousa, C. H., Mercier, M., Rioux-Leclercq, N., Flecher, E., Bendavid, C., Val-Laillet, D., Ferrant, J., Jaillard, S., Loiseau, E., Branchereau, J., Berkane, Y., Nyangoh Timoh, K., Carton, I., Le Lous, M., Lavoue, V., & Dion, L. (2025). Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.15056

Vancouver

Sousa CH, Mercier M, Rioux-Leclercq N, Flecher E, Bendavid C, Val-Laillet D, et al. Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation. Acta Obstetricia et Gynecologica Scandinavica. 2025. doi:10.1111/aogs.15056

BibTeX
@article{Sousa2025,
  author = {Sousa, Carla Héléna and Mercier, Marion and Rioux-Leclercq, Nathalie and Flecher, Erwan and Bendavid, Claude and Val-Laillet, David and Ferrant, Juliette and Jaillard, Sylvie and Loiseau, Emma and Branchereau, Julien and Berkane, Yanis and Nyangoh Timoh, Krystel and Carton, Isis and Le Lous, Maëla and Lavoue, Vincent and Dion, Ludivine},
  title = {Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation},
  journal = {Acta Obstetricia et Gynecologica Scandinavica},
  year = {2025},
  doi = {10.1111/aogs.15056}
}
Start for free →