Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation
Acta Obstetricia et Gynecologica Scandinavica · 2025
DOI: 10.1111/aogs.15056 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Obstetricia et Gynecologica Scandinavica, 2025. Verfasst von Carla Héléna Sousa und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gynecology, Rennes University Hospital, Hôpital Sud, Rennes, France. Hauptthemen laut MEDLINE: Uterus, Organ Preservation, Perfusion, Hypothermia, Induced. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Société de Chirurgie Gynécologie et Pelvienne & Gedeon Richter.
Abstract (Originalsprache)
Introduction
Graft optimization is a necessity in order to develop uterus transplantation from brain‐dead donors, as a complement to living donors, as these grafts are rare and the last organs retrieved in multiple organ donation. The aim of this study was to assess the feasibility and interest of hypothermic machine perfusion (HMP) in uterus transplantation using a porcine model; secondary outcomes were the evaluation of the graft's tolerance to a prolonged cold ischaemia time and to find new biomarkers of uterus viability. Material and Methods Fifteen uterus allotransplantations were performed in a porcine model, after 18 h of cold ischaemia, divided in three groups: Static cold storage in a HTK solution, HMP (with the VitaSmart (™) machine Bridge to Life Ltd.) with a UW‐MP solution, and static cold storage in a UW solution. The main outcome was macroscopic: uterine arteries pulsatility, recoloration, and bleeding at the cut. Secondary outcomes were histological analyses (Zitkute and inflammation scores), caspase3 immunohistochemistry and plasmatic dosage of biomarkers.
Results
14/15 allotransplantations were performed according to the protocol and met the criteria of macroscopic vitality. Grafts treated with HMP (MP did not show significantly more tissue) damage than the recipient's uterus, contrary to grafts in static cold storage, independently of the solution used. This difference disappeared one and 3 h after uterus transplantation. Plasma dosages before and after uterus transplantation did not allow to identify a new biomarker of uterus viability.
Conclusions
HMP is feasible in a porcine model, without inflicting damage on the grafts during cold ischaemia time. Grafts exposed to HMP seemed to better endure reperfusion phenomena, but this advantage did not last over time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Gynecology, Rennes University Hospital, Hôpital Sud, Rennes, France.
- Institute for Research in Health, Environment and Work (Irset), Rennes, France.
- Department of Pathology, Rennes University Hospital, Hôpital Pontchaillou, France.
- Department of Cardiothoracic and Vascular Surgery, Rennes University Hospital, Hôpital Pontchaillou, Rennes, France.
- Laboratory of Biochemistry, Rennes University Hospital, Hôpital Pontchaillou, Rennes, France.
- INRAE, INSERM, University Of Rennes, NuMeCan Institute, Nutrition Metabolisms And Cancer, Rennes, France.
ORCID-Profile: Carla Héléna Sousa, Juliette Ferrant, Isis Carton
Förderung
- Société de Chirurgie Gynécologie et Pelvienne & Gedeon Richter
Zitieren
APA
Sousa, C. H., Mercier, M., Rioux-Leclercq, N., Flecher, E., Bendavid, C., Val-Laillet, D., Ferrant, J., Jaillard, S., Loiseau, E., Branchereau, J., Berkane, Y., Nyangoh Timoh, K., Carton, I., Le Lous, M., Lavoue, V., & Dion, L. (2025). Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1111/aogs.15056
Vancouver
Sousa CH, Mercier M, Rioux-Leclercq N, Flecher E, Bendavid C, Val-Laillet D, et al. Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation. Acta Obstetricia et Gynecologica Scandinavica. 2025. doi:10.1111/aogs.15056
BibTeX
@article{Sousa2025,
author = {Sousa, Carla Héléna and Mercier, Marion and Rioux-Leclercq, Nathalie and Flecher, Erwan and Bendavid, Claude and Val-Laillet, David and Ferrant, Juliette and Jaillard, Sylvie and Loiseau, Emma and Branchereau, Julien and Berkane, Yanis and Nyangoh Timoh, Krystel and Carton, Isis and Le Lous, Maëla and Lavoue, Vincent and Dion, Ludivine},
title = {Hypothermic machine perfusion in uterus transplantation in a porcine model: A proof of concept and the first results in graft preservation},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2025},
doi = {10.1111/aogs.15056}
}
EUVIMED