EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

In vitro biomechanical properties of porcine perineal tissues to better understand human perineal tears during delivery

Marine Lallemant iD, Tiguida Kadiakhe, Jerôme Chambert, Arnaud Lejeune, Rajeev Ramanah, Nicolas Mottet, Emmanuelle Jacquet

Acta Obstetricia et Gynecologica Scandinavica · 2024-07 · 103 (7) · 1386-1395

DOI: 10.1111/aogs.14791 ↗

At a glance

Journal article in Acta Obstetricia et Gynecologica Scandinavica, published online on 2024-03-29. Written by Marine Lallemant and 6 co-authors. Institution: Department of Gynecology and Obstetrics, Besancon University Medical Center, Besançon, France. Major MEDLINE topics: Perineum. Cited 9 times so far (Crossref); 44 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Data concerning the mechanical properties of the perineum during delivery are very limited. In vivo experiments raise ethical issues. The aim of the study was to describe some of the biomechanical properties of each perineal tissue layer collected from sows in order to better understand perineal tears during childbirth. Material and methods Samples of each perineal tissue layer were obtained from the skin, the vagina, the external anal sphincter (EAS), the internal anal sphincter (IAS), and the anal mucosa of fresh dead sows. They were tested in quasi‐static uniaxial tension using the testing machine Mach‐1®. Tests were performed at a displacement velocity of 0.1 mm·s −1 . Stress–strain curves of each perineal tissue layer before the first damage for each sow were obtained and modeled using a hyperelastic Yeoh model described by three coefficients: C1, C2, and C3. Pearson correlation coefficients were calculated to measure the correlation between the C1 hyperelastic coefficient and the duration between the first microfailure and the complete rupture for each perineal tissue layer. Pearson correlation was computed between C1 and the number of microfailures before complete rupture for each tissue.

Results

Ten samples of each perineal tissue layer were analyzed. Mean values of C1 and corresponding standard deviations were 46 ± 15, 165 ± 60, 27 ± 10, 19 ± 13, 145 ± 28 kPa for the perineal skin, the vagina, the EAS, the IAS, and the anal mucosa, respectively. According to this same sample order, the first microfailure in the population of 10 sows appeared at an average of 54%, 27%, 70%, 131%, and 22% of strain. A correlation was found between C1 hyperelastic coefficient and the duration between the first microfailure and the complete rupture ( r = 0.7, p = 0.02) or the number of microfailures before complete rupture only for the vagina ( r = 0.7, p = 0.02).

Conclusions

In this population of fresh dead sow's perineum, the vagina and the anal mucosa were the stiffest tissues. The IAS and EAS were more extensible and less stiff. A significantly positive correlation was found between C1 and the duration between the first microfailure and the complete rupture of the vagina, and the duration between the first microfailure and the complete rupture of the vagina.

Subjects

MeSH terms (MEDLINE)

PerineumAnimalsFemaleSwineBiomechanical PhenomenaHumansPregnancyDelivery, ObstetricIn Vitro TechniquesAnal CanalVagina

Author keywords

biomechanical propertieschildbirthdeformationperineal tearperineumrupturestress–strain curve

Authors and institutions

  • Department of Gynecology and Obstetrics, Besancon University Medical Center, Besançon, France.
  • Department of Applied Mechanics, FEMTO-ST Institute, University of Franche-Comte, UMR 6174 CNRS, Besançon, France.
  • Nanomedicine Imaging and Therapeutics Laboratory, INSERM EA 4662, University of Franche-Comte, Besançon, France.

ORCID profiles: Marine Lallemant

Cite

APA

Lallemant, M., Kadiakhe, T., Chambert, J., Lejeune, A., Ramanah, R., Mottet, N., & Jacquet, E. (2024). In vitro biomechanical properties of porcine perineal tissues to better understand human perineal tears during delivery. Acta Obstetricia et Gynecologica Scandinavica, 103(7), 1386-1395. https://doi.org/10.1111/aogs.14791

Vancouver

Lallemant M, Kadiakhe T, Chambert J, Lejeune A, Ramanah R, Mottet N, et al. In vitro biomechanical properties of porcine perineal tissues to better understand human perineal tears during delivery. Acta Obstetricia et Gynecologica Scandinavica. 2024;103(7):1386-1395. doi:10.1111/aogs.14791

BibTeX
@article{Lallemant2024,
  author = {Lallemant, Marine and Kadiakhe, Tiguida and Chambert, Jerôme and Lejeune, Arnaud and Ramanah, Rajeev and Mottet, Nicolas and Jacquet, Emmanuelle},
  title = {In vitro biomechanical properties of porcine perineal tissues to better understand human perineal tears during delivery},
  journal = {Acta Obstetricia et Gynecologica Scandinavica},
  year = {2024},
  volume = {103},
  number = {7},
  pages = {1386--1395},
  doi = {10.1111/aogs.14791}
}
Start for free →