The development and evaluation of a homemade laparoscopic endotrainer using the IDEAL framework and MISTELS scoring system: a pilot study

Muhammad Usman Malik iD, Tara M Connelly iD, Naila Akhtar Awan, Fatima Rizwan Bhatti, Rana Saddaqat Hayat, Hafiz Riaz Hussain Awan

ANZ Journal of Surgery · 2024

DOI: 10.1111/ans.18865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ANZ Journal of Surgery, 2024. Verfasst von Muhammad Usman Malik und 5 weiteren Autor:innen. Beteiligte Einrichtung: District Surgical Department, District Headquarter Teaching Hospital, Sargodha, Pakistan. Hauptthemen laut MEDLINE: Laparoscopy, Internship and Residency. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A prospective IDEAL stage 2a pilot study was carried out at a tertiary care center to evaluate the reliability of a homemade laparoscopic endotrainer, following the MISTEL and IDEAL framework guidelines.

Methods

The validated modified (MISTELS) score was used to test the reliability of a low‐cost laparoscopic trainer with commonly found components built by surgeons. Basic household materials including a cellular phone (camera source), wifi (linking source) and freely available webcam apps were used for construction. Five basic laparoscopic skills were performed by general surgery resident volunteers with minimal (1–6 months') laparoscopic surgery experience and tested and retested based on efficiency and precision. To determine interrater reliability, two trained observers scored all subjects. The Cronbach alpha test was used to test for internal consistency between tasks. The Interclass correlation coefficient is used for test and retest reliability.

Results

15 (80% male, mean age 28 ± 5 years) residents were included. The interrater and test–retest reliabilities for the total scores of the basic laparoscopic skills tests were 0.952 (95% CI, 0.895–0.981) and 0.64 (95% CI, 0.35–0.77), respectively. The Cronbach Alpha for the first assessment test and retest was 0.83. The MISTELS metrics had excellent reliability, exceeding the threshold level of 0.8.

Conclusion

It is possible to assemble a low‐cost, reliable trainer at home to enhance laparoscopic skills during residency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopyInternship and ResidencyHumansMaleYoung AdultAdultFemalePilot ProjectsReproducibility of ResultsProspective StudiesClinical Competence

Stichwörter der Autor:innen

IDEAL frames workMISTELS scorehomemade endotrainerlaparoscopic surgerysurgical educationsurgical simulation

Autor:innen und Institutionen

  • District Surgical Department, District Headquarter Teaching Hospital, Sargodha, Pakistan.
  • Department of Colon and Rectal Surgery, University Hospital, Limerick, Ireland.
  • Department of Dermatology, Rana Medical Complex, Jauharabad, Pakistan.
  • Department of Psychiatry, Pakistan Institute of Medical Sciences, Islamabad, Pakistan.

ORCID-Profile: Muhammad Usman Malik, Tara M Connelly

Zitieren

APA

Malik, M. U., Connelly, T. M., Awan, N. A., Bhatti, F. R., Hayat, R. S., & Awan, H. R. H. (2024). The development and evaluation of a homemade laparoscopic endotrainer using the IDEAL framework and MISTELS scoring system: a pilot study. ANZ Journal of Surgery. https://doi.org/10.1111/ans.18865

Vancouver

Malik MU, Connelly TM, Awan NA, Bhatti FR, Hayat RS, Awan HRH. The development and evaluation of a homemade laparoscopic endotrainer using the IDEAL framework and MISTELS scoring system: a pilot study. ANZ Journal of Surgery. 2024. doi:10.1111/ans.18865

BibTeX
@article{Malik2024,
  author = {Malik, Muhammad Usman and Connelly, Tara M and Awan, Naila Akhtar and Bhatti, Fatima Rizwan and Hayat, Rana Saddaqat and Awan, Hafiz Riaz Hussain},
  title = {The development and evaluation of a homemade laparoscopic endotrainer using the IDEAL framework and MISTELS scoring system: a pilot study},
  journal = {ANZ Journal of Surgery},
  year = {2024},
  doi = {10.1111/ans.18865}
}