EUVIMEDEUVIMED entdecken
Crossref

Black‐Blood Magnetization Prepared 2 Rapid Acquisition Gradient Echoes: A Fast and Three‐Dimensional MR Black‐Blood T 1 Mapping Technique for Quantitative Assessment of Atherosclerosis and Venous Thrombosis

Yuhui Nie iD, Na Lu, Liping Liao, Zeping Liu, Anyan Gu, Xin Huang, Changjun Tie, Hongyan Liu, Zehe Huang, Guoxi Xie iD

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29156 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Yuhui Nie und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, The Sixth Affiliated Hospital, Guangzhou Medical University, Guangzhou, Guangdong, China. Hauptthemen laut MEDLINE: Phantoms, Imaging, Atherosclerosis, Venous Thrombosis, Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: The Science Foundation of The Sixth Affiliated Hospital of Guangzhou Medical University, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Blood flow signals may be a confounder in quantifying T 1 values of plaque or thrombus and how to realize black‐blood T 1 mapping remains a challenge task.

Purpose

To develop a fast and three‐dimensional black‐blood T 1 mapping technique for quantitative assessment of atherosclerosis and venous thrombosis. Study Type Sequence development and optimization via phantoms and volunteers as well as pilot prospective. Phantom and Subjects Numerical simulations, a standard phantom, 8 healthy volunteers (mean age, 22 ± 1 years; 5 males), and 19 patients (mean age, 57 ± 14 years; 13 males) with atherosclerosis or venous thrombosis. Field Strength/Sequence 3T/inversion recovery spin‐echo sequence (IR‐SE), magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE), and black‐blood prepared MP2RAGE (BB‐MP2RAGE). Assessment The black‐blood preparation (i.e., delay alternating with nutation for tailored excitation, DANTE) was incorporated into MP2RAGE for black‐blood T 1 mapping. The BB‐MP2RAGE was optimized numerically based on the Bloch equation, and then the phantom study was performed to verify the accuracy of T 1 mapping by BB‐MP2RAGE against IR‐SE and MP2RAGE. Preliminary clinical validation was prospectively performed to assess the flow suppression effect and its potential application in plaque and thrombosis identification. Statistical Tests Pearson correlation test, Bland–Altman analysis, paired t ‐test, and intraclass correlation coefficient. A P value 0.99); Compared to MP2RAGE, BB‐MP2RAGE effectively nulled the blood flow signals, and had a significant improvement in contrast‐to‐noise ratio between static tissue and blood (250.5 ± 66.6 vs. 91.9 ± 35.9). BB‐MP2RAGE can quantify plaque or thrombus T 1 relaxation time with blood flow signal suppression. Data Conclusion Accurate T 1 mapping with sufficient blood flow suppression was achieved by BB‐MP2RAGE. BB‐MP2RAGE has the potential to quantitatively characterize atherosclerosis and venous thrombosis. Level of Evidence 1 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingAtherosclerosisVenous ThrombosisImaging, Three-DimensionalMagnetic Resonance ImagingHumansFemaleMiddle AgedMaleAdultProspective StudiesYoung AdultAgedPilot ProjectsReproducibility of ResultsImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

T1 mappingatherosclerosisblack‐blood imagingvenous thrombosis

Autor:innen und Institutionen

  • School of Biomedical Engineering, The Sixth Affiliated Hospital, Guangzhou Medical University, Guangzhou, Guangdong, China.
  • Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
  • Department of Radiology, The First People's Hospital of Qinzhou, Qinzhou, China.
  • Paul C. Lauterbur Imaging Center, Shenzhen Institutes Advanced Technology, Shenzhen, Guangdong, China.

ORCID-Profile: Yuhui Nie, Guoxi Xie

Förderung

  • The Science Foundation of The Sixth Affiliated Hospital of Guangzhou Medical University
  • National Natural Science Foundation of China

Zitieren

APA

Nie, Y., Lu, N., Liao, L., Liu, Z., Gu, A., Huang, X., Tie, C., Liu, H., Huang, Z., & Xie, G. (2024). Black‐Blood Magnetization Prepared 2 Rapid Acquisition Gradient Echoes: A Fast and Three‐Dimensional MR Black‐Blood T 1 Mapping Technique for Quantitative Assessment of Atherosclerosis and Venous Thrombosis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29156

Vancouver

Nie Y, Lu N, Liao L, Liu Z, Gu A, Huang X, et al. Black‐Blood Magnetization Prepared 2 Rapid Acquisition Gradient Echoes: A Fast and Three‐Dimensional MR Black‐Blood T 1 Mapping Technique for Quantitative Assessment of Atherosclerosis and Venous Thrombosis. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29156

BibTeX
@article{Nie2024,
  author = {Nie, Yuhui and Lu, Na and Liao, Liping and Liu, Zeping and Gu, Anyan and Huang, Xin and Tie, Changjun and Liu, Hongyan and Huang, Zehe and Xie, Guoxi},
  title = {Black‐Blood Magnetization Prepared 2 Rapid Acquisition Gradient Echoes: A Fast and Three‐Dimensional MR Black‐Blood T 1 Mapping Technique for Quantitative Assessment of Atherosclerosis and Venous Thrombosis},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29156}
}
Kostenlos starten →