Predicting Ventricular Tachyarrhythmias in Patients With Left Ventricular Ejection Fraction Improvement Following Cardiac Resynchronization Therapy
Annals of Noninvasive Electrocardiology · 2025-05 · 30 (3)
DOI: 10.1111/anec.70059 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Annals of Noninvasive Electrocardiology, online erschienen am 08.04.2025. Verfasst von Adam Visca und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Clinical Cardiovascular Research Center, School of Medicine and Dentistry, University of Rochester, Rochester, New York, USA. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Stroke Volume, Tachycardia, Ventricular, Heart Failure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Patients undergoing cardiac resynchronization therapy with a defibrillator (CRT‐D) often experience improvements in the left ventricular ejection fraction (LVEF). This study aimed to identify predictors of ventricular tachyarrhythmias (VTA) in patients with CRT‐D devices and LVEF improvement beyond guideline recommendations for a defibrillator.
Methods
Patients randomized to the CRT‐D arm of the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy trial who improved their LVEF to > 35% at 12 months following CRT‐D implant were included in this analysis ( N = 651). Predictors of an appropriate implantable cardioverter defibrillator (ICD) Rx VTA were evaluated by Cox proportional hazards regression modeling.
Results
We identified three predictors of VTA among patients treated with CRT‐D subsequent to LVEF improvement > 35%: Lower range improvement in LVEF 36%–40% versus improvement to > 40% (HR, 1.97; 95% CI, 1.21–3.20; p = 0.006); Baseline non‐LBBB ECG morphology (hazard ratio [HR], 1.93; 95% confidence interval [CI], 1.23–3.04; p = 0.004); Occurrence of VTA during the first year post‐CRT‐D (HR, 4.91; 95% CI, 2.99–8.07; p < 0.001).
Conclusions
We identified a sub‐group of patients with risk factors who remain at high risk of VTA despite improvement in LVEF following CRT implant. These patients require close monitoring despite improvement in LVEF beyond guideline recommendations for an ICD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Clinical Cardiovascular Research Center, School of Medicine and Dentistry, University of Rochester, Rochester, New York, USA.
ORCID-Profile: Adam Visca, Mehmet Aktas, Valentina Kutyifa
Zitieren
APA
Visca, A., Sherazi, S., Goldenberg, I., McNitt, S., Rao, N., Rao, N., Shah, A., Aktas, M., Kutyifa, V., Zareba, W., & Rao, K. (2025). Predicting Ventricular Tachyarrhythmias in Patients With Left Ventricular Ejection Fraction Improvement Following Cardiac Resynchronization Therapy. Annals of Noninvasive Electrocardiology, 30(3). https://doi.org/10.1111/anec.70059
Vancouver
Visca A, Sherazi S, Goldenberg I, McNitt S, Rao N, Rao N, et al. Predicting Ventricular Tachyarrhythmias in Patients With Left Ventricular Ejection Fraction Improvement Following Cardiac Resynchronization Therapy. Annals of Noninvasive Electrocardiology. 2025;30(3). doi:10.1111/anec.70059
BibTeX
@article{Visca2025,
author = {Visca, Adam and Sherazi, Saadia and Goldenberg, Ilan and McNitt, Scott and Rao, Nikhila and Rao, Nilesh and Shah, Ahmed and Aktas, Mehmet and Kutyifa, Valentina and Zareba, Wojciech and Rao, Krishna},
title = {Predicting Ventricular Tachyarrhythmias in Patients With Left Ventricular Ejection Fraction Improvement Following Cardiac Resynchronization Therapy},
journal = {Annals of Noninvasive Electrocardiology},
year = {2025},
volume = {30},
number = {3},
doi = {10.1111/anec.70059}
}