EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of signal quality measured with a smart 12‐lead ECG acquisition T‐shirt

David Fouassier, Xavier Roy, Anne Blanchard, Jean-Sébastien Hulot iD

Annals of Noninvasive Electrocardiology · 2020-01 · 25 (1)

DOI: 10.1111/anec.12682 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, online erschienen am 24.07.2019. Verfasst von David Fouassier und 3 weiteren Autor:innen. Beteiligte Einrichtung: Assistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France. Hauptthemen laut MEDLINE: Clothing. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bioserenity, Paris, France.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ambulatory ECG monitoring is typically achieved using portable devices with limited number of surface leads, autonomy, and length of recording. Smart garments with multiple conductive textile electrodes provide great promise to perform continuous and comfortable ECG monitoring.

Methods

We evaluated the ECG signal quality measured on healthy subjects with a smart 12‐lead ECG acquisition T‐shirt or a 12‐lead Holter recording. ECG signals were recorded during 3 min with both techniques in three resting positions (supine, seated, standing) and while walking. Three readers independently assessed ECG patterns and evaluated the denoising of the isoelectric line, the distinction of p waves, R peaks and RR intervals, and the possible appreciation of cardiac rhythm in at least 3 leads.

Results

Thirty healthy subjects (70% males, 29.5 ± 7.8 years) were enrolled in the study. For all three resting conditions, cardiac rhythm was appreciated in 100% of recordings with distinction of p waves, R peaks, and isoelectric line in >97% of recordings. Appreciation of cardiac rhythm was lower in the walking conditions with both techniques (53.3% vs. 46.7%, Holter vs. smart T‐shirt, p = .60) mainly due to difficulties to distinguish p waves. These results were consistent across both genders. All ECG parameters (heart rate, PR, QRS and QTC intervals) were comparable between both techniques. No skin irritation was seen with the textile electrodes.

Conclusions

A smart T‐shirt with 13 textiles electrodes allows short‐duration 12‐lead ECG acquisition with quality levels comparable to Holter recordings. The novel device should now be evaluated for long‐term non‐invasive ECG monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClothingAdultElectrocardiography, AmbulatoryFemaleHumansMaleProspective StudiesReference ValuesReproducibility of ResultsSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

ECGHoltercardiologye-textilegarmenttelemedicinewearable

Autor:innen und Institutionen

  • Assistance Publique Hôpitaux de Paris, Centre d'Investigations Cliniques CIC1418, Hôpital Européen Georges Pompidou, Paris, France.
  • Paris Cardiovascular Research Center PARCC, Inserm UMR970, Paris, France.

ORCID-Profile: Jean-Sébastien Hulot

Förderung

  • Bioserenity, Paris, France

Zitieren

APA

Fouassier, D., Roy, X., Blanchard, A., & Hulot, J. S. (2020). Assessment of signal quality measured with a smart 12‐lead ECG acquisition T‐shirt. Annals of Noninvasive Electrocardiology, 25(1). https://doi.org/10.1111/anec.12682

Vancouver

Fouassier D, Roy X, Blanchard A, Hulot JS. Assessment of signal quality measured with a smart 12‐lead ECG acquisition T‐shirt. Annals of Noninvasive Electrocardiology. 2020;25(1). doi:10.1111/anec.12682

BibTeX
@article{Fouassier2020,
  author = {Fouassier, David and Roy, Xavier and Blanchard, Anne and Hulot, Jean-Sébastien},
  title = {Assessment of signal quality measured with a smart 12‐lead ECG acquisition T‐shirt},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2020},
  volume = {25},
  number = {1},
  doi = {10.1111/anec.12682}
}
Kostenlos starten →