EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison Between a Single-Lead ECG Garment Device and a Holter Monitor: A Signal Quality Assessment

Luca Neri, Ivan Corazza, Matt T Oberdier, Jessica Lago, Ilaria Gallelli, Arrigo F G Cicero, Igor Diemberger, Alessandro Orro, Amir Beker, Nazareno Paolocci, Henry R Halperin, Claudio Borghi

Journal of Medical Systems · 27.05.2024 · 48 (1)

DOI: 10.1007/s10916-024-02077-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Medical Systems, online erschienen am 27.05.2024. Verfasst von Luca Neri und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Cardiology, Johns Hopkins University, 1721 East Madison Street Traylor Hall 901, Baltimore, MD, 21205, USA. Hauptthemen laut MEDLINE: Electrocardiography, Ambulatory, Electrocardiography. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alma Mater Studiorum - Università di Bologna.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20–82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as “Good”, 12% as “Acceptable”, and 18% as “Not Readable”. The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrocardiography, AmbulatoryElectrocardiographyHumansFemaleMaleMiddle AgedAgedAdultAged, 80 and overWearable Electronic DevicesYoung AdultClothingSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

ElectrocardiogramHolter monitorSignal qualityWearable devices

Autor:innen und Institutionen

  • Department of Medicine, Division of Cardiology, Johns Hopkins University, 1721 East Madison Street Traylor Hall 901, Baltimore, MD, 21205, USA.
  • Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy.
  • Cardiovascular Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
  • Cardiology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
  • Institute for Biomedical Technologies, National Research Council (ITB-CNR), Segrate, Italy.
  • Accurate Group S.p.A., L'Aquila, Italy.

Förderung

  • Alma Mater Studiorum - Università di Bologna

Zitieren

APA

Neri, L., Corazza, I., Oberdier, M. T., Lago, J., Gallelli, I., Cicero, A. F. G., Diemberger, I., Orro, A., Beker, A., Paolocci, N., Halperin, H. R., & Borghi, C. (2024). Comparison Between a Single-Lead ECG Garment Device and a Holter Monitor: A Signal Quality Assessment. Journal of Medical Systems, 48(1). https://doi.org/10.1007/s10916-024-02077-9

Vancouver

Neri L, Corazza I, Oberdier MT, Lago J, Gallelli I, Cicero AFG, et al. Comparison Between a Single-Lead ECG Garment Device and a Holter Monitor: A Signal Quality Assessment. Journal of Medical Systems. 2024;48(1). doi:10.1007/s10916-024-02077-9

BibTeX
@article{Neri2024,
  author = {Neri, Luca and Corazza, Ivan and Oberdier, Matt T and Lago, Jessica and Gallelli, Ilaria and Cicero, Arrigo F G and Diemberger, Igor and Orro, Alessandro and Beker, Amir and Paolocci, Nazareno and Halperin, Henry R and Borghi, Claudio},
  title = {Comparison Between a Single-Lead ECG Garment Device and a Holter Monitor: A Signal Quality Assessment},
  journal = {Journal of Medical Systems},
  year = {2024},
  volume = {48},
  number = {1},
  doi = {10.1007/s10916-024-02077-9}
}