Übersichtsarbeit in Australian Endodontic Journal, published online on 2026-11-15. Written by Lucas Peixoto de Araújo and 4 co-authors. Institution: Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA. 86 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

This scoping review mapped evidence on nickel‐titanium instrumentation without a prior glide path across kinematics, models and outcomes. Six databases were searched from inception to August 2026 for studies using rotary or reciprocating nickel‐titanium instruments without a prior glide path and reporting working length attainment or a procedural outcome. Sixty‐nine studies were included, 65 laboratory and four clinical, none providing a randomised comparison of glide‐path omission. Thirteen addressed reaching the full working length, eleven using single‐file reciprocating instruments, which reached it in 85.6%–96.3% of 1773 canals clinically and 70.9%–100% in the laboratory. The remaining 56 reported procedural outcomes. Kinematics, alloy and taper covaried, and the no‐glide‐path condition was defined inconsistently across different systems. Single‐file reciprocating instruments have reached the full working length without a prior glide path in most canals studied, but differences in anatomy, instrument systems and operative protocols limit generalisation.

Subjects

Author keywords

endodontic instrumentsglide pathnickel‐titaniumreciprocationroot canal preparationscoping review

Authors and institutions

  • Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
  • School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Endodontics, Fluminense Federal University, Rio de Janeiro, Brazil.

ORCID profiles: Lucas Peixoto de Araújo, Neville J McDonald, Felipe Gonçalves Belladonna

Cite

APA

de Araújo, L. P., Pham, F., McDonald, N. J., Botero, T. M., & Belladonna, F. G. (2026). Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review. Australian Endodontic Journal. https://doi.org/10.1111/aej.70133

Vancouver

de Araújo LP, Pham F, McDonald NJ, Botero TM, Belladonna FG. Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review. Australian Endodontic Journal. 2026. doi:10.1111/aej.70133

BibTeX
@article{deArajo2026,
  author = {de Araújo, Lucas Peixoto and Pham, Fisher and McDonald, Neville J and Botero, Tatiana M and Belladonna, Felipe Gonçalves},
  title = {Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review},
  journal = {Australian Endodontic Journal},
  year = {2026},
  doi = {10.1111/aej.70133}
}
Start for free →