Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review
Australian Endodontic Journal · 15.11.2026
DOI: 10.1111/aej.70133 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Australian Endodontic Journal, online erschienen am 15.11.2026. Verfasst von Lucas Peixoto de Araújo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA. Die Arbeit nennt 86 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This scoping review mapped evidence on nickel‐titanium instrumentation without a prior glide path across kinematics, models and outcomes. Six databases were searched from inception to August 2026 for studies using rotary or reciprocating nickel‐titanium instruments without a prior glide path and reporting working length attainment or a procedural outcome. Sixty‐nine studies were included, 65 laboratory and four clinical, none providing a randomised comparison of glide‐path omission. Thirteen addressed reaching the full working length, eleven using single‐file reciprocating instruments, which reached it in 85.6%–96.3% of 1773 canals clinically and 70.9%–100% in the laboratory. The remaining 56 reported procedural outcomes. Kinematics, alloy and taper covaried, and the no‐glide‐path condition was defined inconsistently across different systems. Single‐file reciprocating instruments have reached the full working length without a prior glide path in most canals studied, but differences in anatomy, instrument systems and operative protocols limit generalisation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
- School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Endodontics, Fluminense Federal University, Rio de Janeiro, Brazil.
ORCID-Profile: Lucas Peixoto de Araújo, Neville J McDonald, Felipe Gonçalves Belladonna
Zitieren
APA
de Araújo, L. P., Pham, F., McDonald, N. J., Botero, T. M., & Belladonna, F. G. (2026). Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review. Australian Endodontic Journal. https://doi.org/10.1111/aej.70133
Vancouver
de Araújo LP, Pham F, McDonald NJ, Botero TM, Belladonna FG. Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review. Australian Endodontic Journal. 2026. doi:10.1111/aej.70133
BibTeX
@article{deArajo2026,
author = {de Araújo, Lucas Peixoto and Pham, Fisher and McDonald, Neville J and Botero, Tatiana M and Belladonna, Felipe Gonçalves},
title = {Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review},
journal = {Australian Endodontic Journal},
year = {2026},
doi = {10.1111/aej.70133}
}
EUVIMED