EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study

Kavalipurapu Venkata Teja iD, Kaligotla Apoorva Vasundhara, Pradeep Solete iD, Giampiero Rossi-Fedele iD

Australian Endodontic Journal · 2025

DOI: 10.1111/aej.70002 ↗

At a glance

Journal article in Australian Endodontic Journal, 2025. Written by Kavalipurapu Venkata Teja and 3 co-authors. Institution: Department of Conservative Dentistry and Endodontics, Mamata Institute of Dental Sciences, Hyderabad, Telangana, India. Major MEDLINE topics: Root Canal Irrigants, Tooth Apex, Root Canal Preparation, Dental Pulp Cavity. Cited 2 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: GEBR. Brasseler GmbH & Co. KG, Trophagener Weg 25, 32657 Lemgo, Germany..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Accurate working length determination is crucial for root canal treatment. This ex vivo study evaluated the accuracy of a standalone apex locator (Root ZX Mini) and two integrated apex locator‐endomotors (EnDrive and X‐Smart Pro+) under different intracanal conditions. Seventy‐two extracted single‐rooted mandibular premolars were decoronated and standardised. The actual canal length (AML) was determined microscopically, and electronic working lengths (EWL) obtained. Measurements were taken after canal patency and drying with paper points or following irrigation with saline, sodium hypochlorite, or ethylenediaminetetraacetic acid. All devices and intracanal conditions exhibited negative deviations, with EWLs shorter than AML, ranging from −0.15 to −0.50 mm, thus remaining within clinically acceptable limits. Significant differences were observed among devices and canal contents ( p < 0.05), with EnDrive showing the least deviation, particularly in the presence of sodium hypochlorite. These findings support the reliability of integrated apex locator‐endomotors, though measurement accuracy may be affected by irrigant type.

Subjects

MeSH terms (MEDLINE)

Root Canal IrrigantsTooth ApexRoot Canal PreparationDental Pulp CavityOdontometryHumansIn Vitro TechniquesReproducibility of ResultsSodium HypochloriteBicuspid

Author keywords

electronic apex locatorendodonticsintegrated endomotorsodium hypochloriteworking length determination

Substances

Root Canal IrrigantsSodium Hypochlorite

Authors and institutions

  • Department of Conservative Dentistry and Endodontics, Mamata Institute of Dental Sciences, Hyderabad, Telangana, India.
  • Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
  • Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
  • Adelaide Dental School, the University of Adelaide, Adelaide, South Australia, Australia.

ORCID profiles: Kavalipurapu Venkata Teja, Pradeep Solete, Giampiero Rossi-Fedele

Funding

  • GEBR. Brasseler GmbH & Co. KG, Trophagener Weg 25, 32657 Lemgo, Germany.

Cite

APA

Teja, K. V., Vasundhara, K. A., Solete, P., & Rossi-Fedele, G. (2025). Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study. Australian Endodontic Journal. https://doi.org/10.1111/aej.70002

Vancouver

Teja KV, Vasundhara KA, Solete P, Rossi-Fedele G. Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study. Australian Endodontic Journal. 2025. doi:10.1111/aej.70002

BibTeX
@article{Teja2025,
  author = {Teja, Kavalipurapu Venkata and Vasundhara, Kaligotla Apoorva and Solete, Pradeep and Rossi-Fedele, Giampiero},
  title = {Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study},
  journal = {Australian Endodontic Journal},
  year = {2025},
  doi = {10.1111/aej.70002}
}
Start for free →