EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study

Kavalipurapu Venkata Teja iD, Kaligotla Apoorva Vasundhara, Pradeep Solete iD, Giampiero Rossi-Fedele iD

Australian Endodontic Journal · 2025

DOI: 10.1111/aej.70002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Australian Endodontic Journal, 2025. Verfasst von Kavalipurapu Venkata Teja und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Mamata Institute of Dental Sciences, Hyderabad, Telangana, India. Hauptthemen laut MEDLINE: Root Canal Irrigants, Tooth Apex, Root Canal Preparation, Dental Pulp Cavity. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: GEBR. Brasseler GmbH & Co. KG, Trophagener Weg 25, 32657 Lemgo, Germany..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate working length determination is crucial for root canal treatment. This ex vivo study evaluated the accuracy of a standalone apex locator (Root ZX Mini) and two integrated apex locator‐endomotors (EnDrive and X‐Smart Pro+) under different intracanal conditions. Seventy‐two extracted single‐rooted mandibular premolars were decoronated and standardised. The actual canal length (AML) was determined microscopically, and electronic working lengths (EWL) obtained. Measurements were taken after canal patency and drying with paper points or following irrigation with saline, sodium hypochlorite, or ethylenediaminetetraacetic acid. All devices and intracanal conditions exhibited negative deviations, with EWLs shorter than AML, ranging from −0.15 to −0.50 mm, thus remaining within clinically acceptable limits. Significant differences were observed among devices and canal contents ( p < 0.05), with EnDrive showing the least deviation, particularly in the presence of sodium hypochlorite. These findings support the reliability of integrated apex locator‐endomotors, though measurement accuracy may be affected by irrigant type.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal IrrigantsTooth ApexRoot Canal PreparationDental Pulp CavityOdontometryHumansIn Vitro TechniquesReproducibility of ResultsSodium HypochloriteBicuspid

Stichwörter der Autor:innen

electronic apex locatorendodonticsintegrated endomotorsodium hypochloriteworking length determination

Substanzen

Root Canal IrrigantsSodium Hypochlorite

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, Mamata Institute of Dental Sciences, Hyderabad, Telangana, India.
  • Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
  • Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
  • Adelaide Dental School, the University of Adelaide, Adelaide, South Australia, Australia.

ORCID-Profile: Kavalipurapu Venkata Teja, Pradeep Solete, Giampiero Rossi-Fedele

Förderung

  • GEBR. Brasseler GmbH & Co. KG, Trophagener Weg 25, 32657 Lemgo, Germany.

Zitieren

APA

Teja, K. V., Vasundhara, K. A., Solete, P., & Rossi-Fedele, G. (2025). Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study. Australian Endodontic Journal. https://doi.org/10.1111/aej.70002

Vancouver

Teja KV, Vasundhara KA, Solete P, Rossi-Fedele G. Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study. Australian Endodontic Journal. 2025. doi:10.1111/aej.70002

BibTeX
@article{Teja2025,
  author = {Teja, Kavalipurapu Venkata and Vasundhara, Kaligotla Apoorva and Solete, Pradeep and Rossi-Fedele, Giampiero},
  title = {Accuracy of Apex Locator Integrated Endomotors in Estimating Working Length in the Presence of Endodontic Irrigants: An Ex Vivo Study},
  journal = {Australian Endodontic Journal},
  year = {2025},
  doi = {10.1111/aej.70002}
}
Kostenlos starten →