EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Ability of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone

Jonathan Winther Olsen iD, Henrik Wolsted, Rune Sort, Mirjana Cihoric, Nicolai Bang Foss, Jakob Højlund iD

Acta Anaesthesiologica Scandinavica · 2026

DOI: 10.1111/aas.70338 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Acta Anaesthesiologica Scandinavica, 2026. Verfasst von Jonathan Winther Olsen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-Hvidovre, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Algorithms, Stroke Volume, Vasoconstriction, Monitoring, Intraoperative. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Vasoconstriction during anesthesia can influence stroke volume (SV) by preload modulation, making accurate SV monitoring essential to guide vasopressor therapy. Since gold standard methods like pulmonary artery catheterization and lithium dilution provide only intermittent estimates, continuous and less invasive arterial pulse contour analysis systems are increasingly used. However, their accuracy under altered vascular tone remains uncertain. We aimed to evaluate the PulseCO algorithm's (SV‐P) ability to detect clinically relevant changes in SV index (SVI) during manipulation of vascular tone, using lithium dilution with the LiDCO method (CI‐Li) as reference, and to assess how absolute systemic vascular resistance index (SVRI) levels influenced agreement between methods.

Methods

In this prospective observational study, adult patients undergoing general anesthesia were monitored using continuous SV‐P and intermittent CI‐Li at three predefined time points: (1) supine baseline after anesthetic induction, (2) after head‐up tilt (HUT), and (3) during phenylephrine infusion in HUT. Agreement in SVI changes was assessed by directional concordance, absolute changes and Bland–Altman analysis, and the impact of vascular load was further explored by examining SVRI. A ≥ 10% change in SVI was defined as clinically relevant.

Results

A total of 19 patients were included. Directional concordance between the two methods was 100% in both interventions. The SV‐P registered SVI changes ≥ 10% in all patients during both interventions, while lithium dilution registered this in 16 and 18 patients, respectively. The SV‐P consistently overestimated SVI changes compared with CI‐Li, with a non‐significant mean difference of −1.6 mL/m 2 (95% CI: −4.2 to 1.1, p = 0.28) from baseline to HUT, and a significant overestimation during phenylephrine infusion with a mean difference of 4.9 mL/m 2 (95% CI: 2.5 to 7.4, p = 0.001). Relative discrepancies between SV‐P and CI‐Li appeared to increase with higher SVRI.

Conclusion

The arterial pulse wave‐based algorithm detected clinically relevant changes in SVI with 100% sensitivity and showed a 100% concordance with lithium dilution in the direction of change. However, it generally overestimated absolute SVI changes, and most markedly so during phenylephrine administration. Relative discrepancies in absolute SVI values appeared to increase with higher SVRI, highlighting that vascular load affects agreement. Editorial Comment This study compares the performance of one device's pulse contour‐based estimates for stroke volume to estimates of stroke volume, same device, based on dilution‐based cardiac output and observed heart rate. This was also tracked during anesthesia interventions expected to alter peripheral vascular tone. These 2 methods for stroke volume (index) estimation agreed in direction of change with the clinical interventions, while pulse contour analysis appeared to overestimate changes in stroke volume compared to the flow‐based estimates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsStroke VolumeVasoconstrictionMonitoring, IntraoperativeHumansProspective StudiesPhenylephrineMiddle AgedFemaleMaleVasoconstrictor AgentsVascular ResistanceAdultAnesthesia, GeneralAgedTilt-Table Test

Substanzen

PhenylephrineVasoconstrictor Agents

Autor:innen und Institutionen

  • Department of Anesthesiology and Intensive Care, Copenhagen University Hospital-Hvidovre, Copenhagen, Denmark.

ORCID-Profile: Jonathan Winther Olsen, Jakob Højlund

Zitieren

APA

Olsen, J. W., Wolsted, H., Sort, R., Cihoric, M., Foss, N. B., & Højlund, J. (2026). Ability of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/aas.70338

Vancouver

Olsen JW, Wolsted H, Sort R, Cihoric M, Foss NB, Højlund J. Ability of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone. Acta Anaesthesiologica Scandinavica. 2026. doi:10.1111/aas.70338

BibTeX
@article{Olsen2026,
  author = {Olsen, Jonathan Winther and Wolsted, Henrik and Sort, Rune and Cihoric, Mirjana and Foss, Nicolai Bang and Højlund, Jakob},
  title = {Ability of the PulseCO Algorithm to Assess Changes in Stroke Volume Induced by Changes in Vascular Tone},
  journal = {Acta Anaesthesiologica Scandinavica},
  year = {2026},
  doi = {10.1111/aas.70338}
}
Kostenlos starten →