Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients
Acta Anaesthesiologica Scandinavica · 2025-01 · 69 (1)
DOI: 10.1111/aas.14540 ↗At a glance
Journal article in Acta Anaesthesiologica Scandinavica, published online on 2024-10-22. Written by Katalin Kiss and 3 co-authors. Institution: Department of Anesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, …. Major MEDLINE topics: Glomerular Filtration Rate, Critical Illness, Cystatin C, Outpatients. Cited 8 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: John and Brit Wennerström's Research Foundation, The Swedish State under the agreement between the Swedish government and the county councils, the ALF-agreement, The Swedish Kidney Foundation.
Abstract (original language)
Background
Estimating equations for the assessment of glomerular filtration rate (GFR) have been poorly investigated in the critical care setting. We evaluated the agreement between the GFR measured with 51 CrEDTA/iohexol (mGFR) and four estimating equations based on serum concentrations of creatine and/or cystatin C (eGFR) in two cohorts: critically ill patients and outpatients with normal‐to‐moderately reduced GFR.
Methods
Forty‐three patients in the critical care group and 48 patients in the outpatient group were included. GFR was measured (mGFR) by plasma infusion clearance of 51 Cr‐EDTA/iohexol (critical care group) and the single injection, one‐sample plasma 51 Cr‐EDTA clearance technique (outpatients). The following estimating equations (eGFR) were used: the Chronic Kidney Disease Epidemiology Collaboration (CKD‐EPI) equation for creatinine (CKD‐EPI Cr ), cystatin C (CKD‐EPI Cys C ), creatinine+cystatin C (CKD‐EPI Cr + Cys C ) and the Lund‐Malmö creatinine+cystatin C equation (LM Cr + Cys C ). Agreement between mGFR and eGFR was assessed by the Bland–Altman method and accuracy by calculating P30 and P10.
Results
In the critically ill group, the bias between the estimating equations and mGFR was −3.6 to 2.8 mL/min/1.73 m 2 , while the error was 121%–127% and the accuracy (P30) 33%–40%. In the outpatients, the bias between the estimating equations and mGFR was −13.0 to 7.6 mL/min/1.73 m 2 , while the error was 31%–41% and the accuracy (P30), 67%–96%.
Conclusions
All four equations performed poorly in assessing GFR in the critically ill cohort with an unacceptably high error and low accuracy in contrast to the outpatient group. To accurately assess GFR in critically ill patients, GFR must be measured not estimated. Editorial Comment For the assessment of glomerular filtration rate (GFR), it can be measured directly, but is frequently estimated using a point measure of serum creatinine concentration. In this study, ICU case GFR estimations, by different adjusted equations, done also for a cohort of outpatients, showed that these serum creatinine‐based estimations for ICU cases are not highly precise or reliable.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Department of Anesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Department of Molecular and Clinical Medicine/Nephrology, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
ORCID profiles: Sven-Erik Ricksten, Gudrun Bragadottir
Funding
- John and Brit Wennerström's Research Foundation
- The Swedish State under the agreement between the Swedish government and the county councils, the ALF-agreement
- The Swedish Kidney Foundation
- The Swedish Foundation for Kidney Patients
Cite
APA
Kiss, K., Saeed, A., Ricksten, S. E., & Bragadottir, G. (2025). Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients. Acta Anaesthesiologica Scandinavica, 69(1). https://doi.org/10.1111/aas.14540
Vancouver
Kiss K, Saeed A, Ricksten SE, Bragadottir G. Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients. Acta Anaesthesiologica Scandinavica. 2025;69(1). doi:10.1111/aas.14540
BibTeX
@article{Kiss2025,
author = {Kiss, Katalin and Saeed, Aso and Ricksten, Sven-Erik and Bragadottir, Gudrun},
title = {Accuracy of estimating equations for the assessment of glomerular filtration rate in critically ill patients versus outpatients},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2025},
volume = {69},
number = {1},
doi = {10.1111/aas.14540}
}