Incidence, causes, and management of failed awake fibreoptic intubation—A retrospective study of 833 procedures
Acta Anaesthesiologica Scandinavica · 2023-11 · 67 (10) · 1341-1347
DOI: 10.1111/aas.14313 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Anaesthesiologica Scandinavica, online erschienen am 16.08.2023. Verfasst von Kjetil Andreas Hognestad Karlsen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine and Pre-Hospital Services, St. Olav's University Hospital, Trondheim, Norway. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Fiber Optic Technology. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Awake fibreoptic intubation has been considered a gold standard in the management of the difficult airway. However, failure may cause critical situations. The aim of this study was to investigate the incidence and causes of failed awake fibreoptic intubation at a tertiary care hospital. The study was conducted at St. Olav University Hospital in Trondheim, Norway. Problems occurring during anaesthesia are routinely recorded in the electronic anaesthesia information system (Picis Clinical Solutions Inc.), including difficult intubations. We applied text search on all anaesthesia records between 2011 and 2021 and identified 833 awake fibreoptic intubations. The anaesthesia records were examined to identify failed awake fibreoptic intubations, the cause of failure and how the airway ultimately was secured. Among 233,938 patients who received anaesthesia, 90,397 received tracheal intubation and 833 received awake fibreoptic intubation. Twenty‐nine of the procedures failed. In nine patients the failure caused loss of airway control with desaturation and hypoventilation. The major causes of failure were dislodged tube after induction of general anaesthesia ( n = 8), patient distress ( n = 5), tube not able to pass ( n = 5), and airway bleeding ( n = 3). The situations were primarily solved using direct laryngoscopy, with or without bougie, or with video laryngoscopy. Tracheostomy was performed in four patients. Awake fibreoptic intubation failed in 3.5% of patients, most often due to dislocation, problems passing the tracheal tube, or patient discomfort. The failure rate was higher than in previous studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Emergency Medicine and Pre-Hospital Services, St. Olav's University Hospital, Trondheim, Norway.
- Department of Anaesthesia and Intensive Care Medicine, St. Olav's University Hospital, Trondheim, Norway.
- Department of Circulation and Medical Imaging. Faculty of Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.
- Department of Research and Development, Division of Emergencies and Critical Care, Oslo University Hospital, Oslo, Norway.
ORCID-Profile: Trond Nordseth
Zitieren
APA
Karlsen, K. A. H., Gisvold, S. E., Nordseth, T., & Fasting, S. (2023). Incidence, causes, and management of failed awake fibreoptic intubation—A retrospective study of 833 procedures. Acta Anaesthesiologica Scandinavica, 67(10), 1341-1347. https://doi.org/10.1111/aas.14313
Vancouver
Karlsen KAH, Gisvold SE, Nordseth T, Fasting S. Incidence, causes, and management of failed awake fibreoptic intubation—A retrospective study of 833 procedures. Acta Anaesthesiologica Scandinavica. 2023;67(10):1341-1347. doi:10.1111/aas.14313
BibTeX
@article{Karlsen2023,
author = {Karlsen, Kjetil Andreas Hognestad and Gisvold, Sven Erik and Nordseth, Trond and Fasting, Sigurd},
title = {Incidence, causes, and management of failed awake fibreoptic intubation—A retrospective study of 833 procedures},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2023},
volume = {67},
number = {10},
pages = {1341--1347},
doi = {10.1111/aas.14313}
}
EUVIMED