High‐flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy
Acta Anaesthesiologica Scandinavica · 2023-11 · 67 (10) · 1403-1413
DOI: 10.1111/aas.14305 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Anaesthesiologica Scandinavica, online erschienen am 12.07.2023. Verfasst von Peter H Egbers und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical Centre of Leeuwarden, Leeuwarden, The Netherlands. Hauptthemen laut MEDLINE: Tracheostomy, Ventilator Weaning, Respiration, Artificial. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Departmental funding at The Intensive Care Unit of the Medical Centre of Leeuwarden, Leeuwarden, The Netherlands (Peter Egbers), Departmental funding at The Remeo Intensive Care Rehabilitation Center, Stockholm, Sweden (Eva Sundman).
Themen: Beatmung und Weaning
Abstract (Originalsprache)
Background
Weaning from mechanical ventilation and tracheostomy after prolonged intensive care consume enormous resources with optimal management not currently well described. Restoration of respiratory flow via the upper airway is essential and early cuff‐deflation using a one‐way valve (OWV) is recommended. However, extended OWV use may cause dry airways and thickened secretions which challenge the weaning process. High‐flow therapy via the tracheostomy tube (HFT‐T) humidifies inspired air and may be connected via an in‐line OWV (HFT‐T‐OWV) alleviating these problems. We aim to provide clinical and experimental data on the safety of HFT‐T‐OWV along with a practical guide to facilitate clinical use during weaning from mechanical ventilation and tracheostomy.
Methods
Data on adverse events of HFT‐T‐OWV were retrieved from a quality register for patients treated at an intensive care rehabilitation center between 2019 and 2022. Benchtop experiments were performed to measure maximum pressures and pressure support generated by HFT‐T‐OWV at 25–60 L/min flow using two different HFT‐T adapters (interfaces). In simulated airway obstruction using a standard OWV (not in‐line) maximum pressures were measured with oxygen delivered via the side port at 1–3 L/min.
Results
Of 128 tracheostomized patients who underwent weaning attempts, 124 were treated with HFT‐T‐OWV. The therapy was well tolerated, and no adverse events related to the practice were detected. The main reason for not using HFT‐T‐OWV was partial upper airway obstruction using a OWV. Benchtop experiments demonstrated HFT‐T‐OWV maximum pressures
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Centre of Leeuwarden, Leeuwarden, The Netherlands.
- Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia.
- School of Medicine, University of Queensland, Brisbane, Australia.
- Consulting Speech and Language Therapist, Bank Partners, The Royal London Hospital, London, UK.
- Remeo Intensive Care Rehabilitation Center, Stockholm, Sweden.
- Department of Medicine Solna, Karolinska Institutet, Stockholm, Sweden.
ORCID-Profile: Jenny E Petersson, Eva Sundman
Förderung
- Departmental funding at The Intensive Care Unit of the Medical Centre of Leeuwarden, Leeuwarden, The Netherlands (Peter Egbers)
- Departmental funding at The Remeo Intensive Care Rehabilitation Center, Stockholm, Sweden (Eva Sundman)
Zitieren
APA
Egbers, P. H., Sutt, A. L., Petersson, J. E., Bergström, L., & Sundman, E. (2023). High‐flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy. Acta Anaesthesiologica Scandinavica, 67(10), 1403-1413. https://doi.org/10.1111/aas.14305
Vancouver
Egbers PH, Sutt AL, Petersson JE, Bergström L, Sundman E. High‐flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy. Acta Anaesthesiologica Scandinavica. 2023;67(10):1403-1413. doi:10.1111/aas.14305
BibTeX
@article{Egbers2023,
author = {Egbers, Peter H and Sutt, Anna-Liisa and Petersson, Jenny E and Bergström, Liza and Sundman, Eva},
title = {High‐flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2023},
volume = {67},
number = {10},
pages = {1403--1413},
doi = {10.1111/aas.14305}
}
EUVIMED