Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study
Acta Anaesthesiologica Scandinavica · 2023
DOI: 10.1111/aas.14260 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Anaesthesiologica Scandinavica, 2023. Verfasst von Robert G Hahn und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden. Hauptthemen laut MEDLINE: Monitoring, Intraoperative, Hemodynamics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Anaesthesiology and Intensive Care, Linköping University Hospital, and the County Council of Östergötland.
Abstract (Originalsprache)
Background
Fluid therapy during major surgery can be managed by providing repeated bolus infusions until stroke volume no longer increases by ≥ 10%. However, the final bolus in an optimization round increases stroke volume by < 10% and is not necessary. We studied how different cut‐off values for the hemodynamic indications given by esophagus Doppler monitoring, as well as augmentation by pulse oximetry, are associated with a higher or smaller chance that stroke volume increases by ≥ 10% (fluid responsiveness) before fluid is infused.
Methods
An esophagus Doppler and a pulse oximeter that displayed the pleth variability index were used to monitor the effects of a bolus infusion in 108 patients undergoing goal‐directed fluid therapy during major open abdominal surgery.
Results
The analyzed data set comprised 266 bolus infusions. The overall incidence of fluid responsiveness was 44%, but this varied greatly depending on pre‐infusion hemodynamics. The likelihood of being fluid‐responsive was 30%–38% in the presence of stroke volume > 80 mL, corrected flow time > 360 ms, or pleth variability index < 10%. The likelihood was 21% if stroke volume had decreased by 100 mL. By contrast, the likelihood of fluid responsiveness increased to 50%–55% when stroke volume ≤ 50 mL, corrected flow time ≤ 360 ms, or pleth variability index ≥ 10. A decrease in stroke volume by > 8% since the previous optimization was followed by a 58% likelihood of fluid responsiveness that, in combination with any of the other hemodynamic variables, increased to 66%–76%.
Conclusions
Single or combined hemodynamic variables provided by esophagus Doppler monitoring and pulse oximetry derived pleth variability index could help clinicians avoid unnecessary fluid bolus infusions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Sciences at Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
- Department of Anaesthesiology and Intensive Care, Linköping University, Linköping, Sweden.
- Department of Biomedical and Clinical Sciences (BKV), Linköping University, Linköping, Sweden.
ORCID-Profile: Robert G Hahn, Hans Bahlmann
Förderung
- Department of Anaesthesiology and Intensive Care, Linköping University Hospital, and the County Council of Östergötland
Zitieren
APA
Hahn, R. G., Nilsson, L., & Bahlmann, H. (2023). Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/aas.14260
Vancouver
Hahn RG, Nilsson L, Bahlmann H. Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study. Acta Anaesthesiologica Scandinavica. 2023. doi:10.1111/aas.14260
BibTeX
@article{Hahn2023,
author = {Hahn, Robert G and Nilsson, Lena and Bahlmann, Hans},
title = {Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2023},
doi = {10.1111/aas.14260}
}
EUVIMED