Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs
Acta Anaesthesiologica Scandinavica · 2023
DOI: 10.1111/aas.14253 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Anaesthesiologica Scandinavica, 2023. Verfasst von Jacob Karlsson und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden. Hauptthemen laut MEDLINE: Fluid Therapy, Hemodynamics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Maquet Critical Care AB.
Abstract (Originalsprache)
Background
The capnodynamic method, based on Volumetric capnography and differential Fick mathematics, assess cardiac output in mechanically ventilated subjects. Capnodynamic and established hemodynamic monitoring parameters' capability to depict alterations in blood volume were investigated in a model of standardized hemorrhage, followed by crystalloid and blood transfusion.
Methods
Ten anesthetized piglets were subjected to controlled hemorrhage (450 mL), followed by isovolemic crystalloid bolus and blood re‐transfusion. Intravascular blood volume, and all hemodynamic variables, were determined twice after each intervention. The investigated hemodynamic variables were: cardiac output and stroke volume for capnodynamics and pulse contour analysis, respectively, pulse pressure and stroke volume variability and mean arterial pressure. One‐way ANOVA and Tukey's test for multiple comparisons were used to identify significant changes. Trending was assessed by correlation and concordance.
Result
Concordance against intravascular volume changes for capnodynamic cardiac output and stroke volume were 96 and 94%, with correlations r = .78 and .68, ( p < .0001) with significant changes for 6 and 5 of the 6 measuring points, respectively. Mean arterial pressure and pulse pressure variation had a concordance of 85% and 87%, r = .67 ( p < .0001) and r = −.45 ( p < .0001), respectively, and both changed significantly for 3 of 6 measuring points. Pulse contour stroke volume variation, stroke volume and cardiac output, showed concordance and correlation of 76%, r = −.18 ( p = .11), 63%, r = .28 ( p = .01) and 50%, r = .31 ( p = .007), respectively and significant change for 1, 1 and 0 of the measuring points, respectively.
Conclusion
Capnodynamic cardiac output and stroke volume did best depict the changes in intravascular blood volume. Pulse contour parameters did not follow volume changes in a reliable way.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Paediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden.
- Department of Physiology and Pharmacology (Fysiologi och Farmakologi [FYFA]), Karolinska Institute, Stockholm, Sweden.
- Maquet Critical Care Aktiebolag (AB), Solna, Sweden.
ORCID-Profile: Jacob Karlsson, Per-Arne Lönnqvist, Mats Wallin
Förderung
- Maquet Critical Care AB
Zitieren
APA
Karlsson, J., Hallbäck, M., Svedmyr, A., Lönnqvist, P. A., & Wallin, M. (2023). Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/aas.14253
Vancouver
Karlsson J, Hallbäck M, Svedmyr A, Lönnqvist PA, Wallin M. Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs. Acta Anaesthesiologica Scandinavica. 2023. doi:10.1111/aas.14253
BibTeX
@article{Karlsson2023,
author = {Karlsson, Jacob and Hallbäck, Magnus and Svedmyr, Anders and Lönnqvist, Per-Arne and Wallin, Mats},
title = {Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2023},
doi = {10.1111/aas.14253}
}
EUVIMED