Accuracy of colour Doppler ultrasound for nasogastric tube placement in emergency department: A prospective observational study
Emergency Medicine Australasia · 2025
DOI: 10.1111/1742-6723.70020 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Emergency Medicine Australasia, 2025. Verfasst von Ming Yee Ong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Intubation, Gastrointestinal, Ultrasonography, Doppler, Color. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objective
Nasogastric tube (NGT) placement is a common procedure in EDs. Successful NGT placement reduces complications such as aspiration pneumonia, pneumothorax and mortality. While chest radiography is the gold standard for confirmation, colour Doppler ultrasonography (CDU) has demonstrated high accuracy. As its applicability in the ED remains underexplored, the present study evaluates the accuracy of CDU in confirming NGT placement in the ED.
Methods
A prospective observational study was conducted in a tertiary hospital ED from October 2022 to October 2023. Adult patients requiring NGT insertion were eligible. NGT placement was performed using a standardised protocol and confirmed with CDU and chest radiography. Accuracy of CDU was assessed against chest radiography, and procedural times for confirmation were compared using the Kruskal–Wallis H test.
Results
Of 157 patients screened, 144 were included. CDU demonstrated 92.45% (95% confidence interval 85.67–96.69) sensitivity, 80.56% (63.98–91.81) specificity, positive predictive value 0.93 (0.88–0.96), negative predictive value 0.78 (0.64–0.88), positive likelihood ratio 4.75 (2.44–9.27) and negative likelihood ratio 0.09 (0.05–0.19). The median (interquartile range) confirmation times were 3.0 min (2.0–3.0) for CDU and 42.0 min (30.0–55.0) for radiography ( P < 0.001).
Conclusion
CDU should not currently be used as a standalone method for confirming NGT placement due to its limitations and risk of false‐positive results. Further research is required to address these challenges before considering its clinical implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Emergency Medicine, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
- Trauma and Emergency Department, Hospital Melaka, Melaka, Malaysia.
ORCID-Profile: Khadijah Poh
Zitieren
APA
Ong, M. Y., Ahmad Zahedi, A. Z., Zambri, A., Noor Azhar, M., Bustam, A., Mohd Alip, R., Yahya, M. F., & Poh, K. (2025). Accuracy of colour Doppler ultrasound for nasogastric tube placement in emergency department: A prospective observational study. Emergency Medicine Australasia. https://doi.org/10.1111/1742-6723.70020
Vancouver
Ong MY, Ahmad Zahedi AZ, Zambri A, Noor Azhar M, Bustam A, Mohd Alip R, et al. Accuracy of colour Doppler ultrasound for nasogastric tube placement in emergency department: A prospective observational study. Emergency Medicine Australasia. 2025. doi:10.1111/1742-6723.70020
BibTeX
@article{Ong2025,
author = {Ong, Ming Yee and Ahmad Zahedi, Ahmad Zulkarnain and Zambri, Aliyah and Noor Azhar, Muhaimin and Bustam, Aida and Mohd Alip, Rabiha and Yahya, Mohammad Fadhly and Poh, Khadijah},
title = {Accuracy of colour Doppler ultrasound for nasogastric tube placement in emergency department: A prospective observational study},
journal = {Emergency Medicine Australasia},
year = {2025},
doi = {10.1111/1742-6723.70020}
}
EUVIMED