EUVIMEDEUVIMED entdecken
Crossref

Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs

Nikola Radeljic-Jakic, Adriaan J Flikweert, Nuriel N M Rozsa, Hendrik J Vos, Michiel A P Pertijs

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2025

DOI: 10.1109/tuffc.2025.3577258 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2025. Verfasst von Nikola Radeljic-Jakic und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Analog-Digital Conversion, Signal Processing, Computer-Assisted. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Emerging handheld and wearable ultrasound devices enable diagnosis and long-term monitoring outside clinical settings. They require a low-power, highly complex, locally integrated system to process the RF data. The analog-to-digital converter (ADC) is a critical building block in the receive chain of these systems as it enables digital beamforming and image reconstruction. However, the ADCs currently used in cart-based imaging systems are bulky and consume too much power to be integrated into battery-powered devices. This article investigates how the area and power consumption of the commonly used successive approximation register (SAR) ADC can be reduced without negatively affecting B-mode and color-Doppler image quality. A Monte Carlo (MC) simulation study was performed in which RF data acquired with a phased-array transducer in Field II were digitized using a model of a nonideal ADC. Five different nonidealities were applied to four commonly used SAR-ADC architectures. B-mode and color-Doppler images were reconstructed from the digitized RF data. The impact of the nonidealities on the image quality was evaluated by means of three image quality metrics (IQM): peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and contrast-to-noise ratio (CNR). The effectiveness of error correction and ways of calibration are also discussed. The results show that both B-mode imaging and color-Doppler imaging are inherently resilient to nonidealities, particularly capacitor mismatch, leading to relaxed ADC requirements and paving the way for more practical in-probe digitization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedAnalog-Digital ConversionSignal Processing, Computer-AssistedUltrasonographyPhantoms, ImagingEquipment DesignHumansMonte Carlo Method

Zitieren

APA

Radeljic-Jakic, N., Flikweert, A. J., Rozsa, N. N. M., Vos, H. J., & Pertijs, M. A. P. (2025). Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2025.3577258

Vancouver

Radeljic-Jakic N, Flikweert AJ, Rozsa NNM, Vos HJ, Pertijs MAP. Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2025. doi:10.1109/tuffc.2025.3577258

BibTeX
@article{RadeljicJakic2025,
  author = {Radeljic-Jakic, Nikola and Flikweert, Adriaan J and Rozsa, Nuriel N M and Vos, Hendrik J and Pertijs, Michiel A P},
  title = {Using Image Quality Metrics to Optimize the Design of Integrated Medical Ultrasound ADCs},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2025},
  doi = {10.1109/tuffc.2025.3577258}
}
Kostenlos starten →