A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3493602 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Francois Destrempes und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: COVID-19, Erythrocytes, Erythrocyte Aggregation. Die Arbeit nennt 71 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, National Alliance for Accessible Golf.
Abstract (Originalsprache)
The ultrasound backscatter coefficient (BSC) is a frequency-dependent quantity intrinsic to biological tissues that can be recovered from backscattered radio frequency (RF) signals, granted acquisitions on a reference phantom (RP) are available under the same system's settings. A phantom-free (PF) BSC estimation method is proposed based on Gaussian-shaped approximation of the point spread function (PSF) (electronics and piezoelectric characteristics of the scanner's probe) and the effective medium theory combined with the structure factor model (EMTSFM), albeit the proposed approach is amenable to other models. Meanwhile, the total attenuation due to intervening tissues is refined from its theoretical value, which is based on reported average behaviors of tissues, while allowing correction for diffraction due to the probe's geometry. The RP method adapted to a similar approach except for the Gaussian approximation is also presented. The proposed PF and RP methods were compared on ten COVID-19 positive patients and 12 control subjects with measures on femoral veins and arteries. In this context, red blood cells (RBCs) are viewed as scatterers that form aggregates increasing the backscatter under the COVID-19 inflammatory condition. The considered model comprises five parameters, including the mean aggregate size estimated according to the polydispersity of aggregates' radii, and anisotropy of their shape. The mean aggregate size over the two proposed methods presented an intraclass correlation coefficient (ICC) of 0.964 for consistency. The aggregate size presented a significant difference between the two groups with either two methods, despite the confounding effect of the maximum Doppler velocity within the blood vessel and its diameter.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Natural Sciences and Engineering Research Council of Canada
- National Alliance for Accessible Golf
Zitieren
APA
Destrempes, F., Chayer, B., Roy Cardinal, M. H., Allard, L., Rivaz, H., Durand, M., Beaubien-Souligny, W., Girard, M., & Cloutier, G. (2024). A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3493602
Vancouver
Destrempes F, Chayer B, Roy Cardinal MH, Allard L, Rivaz H, Durand M, et al. A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3493602
BibTeX
@article{Destrempes2024,
author = {Destrempes, Francois and Chayer, Boris and Roy Cardinal, Marie-Helene and Allard, Louise and Rivaz, Hassan and Durand, Madeleine and Beaubien-Souligny, William and Girard, Martin and Cloutier, Guy},
title = {A Phantom-Free Approach for Estimating the Backscatter Coefficient of Aggregated Red Blood Cells Applied to COVID-19 Patients},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3493602}
}
EUVIMED