EUVIMEDEUVIMED entdecken
Open Access

Assessing the benefits of using plane wave compounding when estimating backscatter coefficients with an in situ bead as a calibration target

Yuning Zhao iD, Zhengchang Kou iD, Mingrui Liu iD, Rita J Miller, Gregory J Czarnota, Michael L Oelze iD

The Journal of the Acoustical Society of America · 01.05.2026 · 159 (5) · 3896-3909

DOI: 10.1121/10.0043333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 06.05.2026. Verfasst von Yuning Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA. Hauptthemen laut MEDLINE: Ultrasonic Waves, Elasticity Imaging Techniques. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, Foundation for the National Institutes of Health, Zhengchang Kou's funding is Beckman Institute Postdoc Fellowship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative ultrasound (QUS) techniques provide tissue characterization and have applications in precision diagnostics and therapy monitoring. A common QUS approach estimates backscatter coefficients (BSCs) using the external reference phantom method, which does not adequately address attenuation and transmission losses. To address this issue, we previously utilized a 2 mm titanium bead as an in situ calibration reference with conventional focused wave (FW) imaging. Plane wave compounding (PWC), which transmits multiple angled plane waves, enables rapid image acquisition while maintaining quality, making it widely useful in Doppler and elastographic imaging. However, its role in BSC estimation with an in situ bead had not been investigated. We hypothesized that PWC would outperform FW, as diffraction effects vary more slowly away from the bead depth when using PWC. We tested this hypothesis by comparing BSC estimation in phantoms and in vivo rabbit mammary tumors. Results indicated that PWC with in situ calibration better compensated for attenuation loss and reduced variability in scatterer property estimates compared to FW. Specifically, the scatterer diameter variance was 15.2 μm2 when using PWC versus 45.4 μm2 when using FW where the focus was offset from the bead depth. These findings demonstrate the superiority of using PWC with an in situ calibration target for accurate, efficient BSC estimation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonic WavesElasticity Imaging TechniquesAnimalsCalibrationRabbitsPhantoms, ImagingFemaleScattering, RadiationUltrasonographyTitanium

Substanzen

Titanium

Autor:innen und Institutionen

  • Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
  • Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
  • Department of Medical Biophysics and Radiation Oncology, University of Toronto, Toronto, Ontario, Canada.
  • Department of Imaging Research and Radiation Oncology, Sunnybrook Health Sciences Center, Toronto, Toronto, Ontario, Canada.
  • Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.

ORCID-Profile: Yuning Zhao, Zhengchang Kou, Mingrui Liu, Michael L Oelze

Förderung

  • NCI NIH HHS
  • Foundation for the National Institutes of Health
  • Zhengchang Kou's funding is Beckman Institute Postdoc Fellowship

Zitieren

APA

Zhao, Y., Kou, Z., Liu, M., Miller, R. J., Czarnota, G. J., & Oelze, M. L. (2026). Assessing the benefits of using plane wave compounding when estimating backscatter coefficients with an in situ bead as a calibration target. The Journal of the Acoustical Society of America, 159(5), 3896-3909. https://doi.org/10.1121/10.0043333

Vancouver

Zhao Y, Kou Z, Liu M, Miller RJ, Czarnota GJ, Oelze ML. Assessing the benefits of using plane wave compounding when estimating backscatter coefficients with an in situ bead as a calibration target. The Journal of the Acoustical Society of America. 2026;159(5):3896-3909. doi:10.1121/10.0043333

BibTeX
@article{Zhao2026,
  author = {Zhao, Yuning and Kou, Zhengchang and Liu, Mingrui and Miller, Rita J and Czarnota, Gregory J and Oelze, Michael L},
  title = {Assessing the benefits of using plane wave compounding when estimating backscatter coefficients with an in situ bead as a calibration target},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {159},
  number = {5},
  pages = {3896--3909},
  doi = {10.1121/10.0043333}
}
Kostenlos starten →