ULM-MbCNRT: In Vivo Ultrafast Ultrasound Localization Microscopy by Combining Multibranch CNN and Recursive Transformer
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3388102 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Gaobo Zhang und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Neural Networks, Computer, Deep Learning, Microscopy, Acoustic. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Explorer Program of Shanghai.
Abstract (Originalsprache)
Ultrasound localization microscopy (ULM) overcomes the acoustic diffraction limit by localizing tiny microbubbles (MBs), thus enabling the microvascular to be rendered at subwavelength resolution. Nevertheless, to obtain such superior spatial resolution, it is necessary to spend tens of seconds gathering numerous ultrasound (US) frames to accumulate the MB events required, resulting in ULM imaging still suffering from tradeoffs between imaging quality, data acquisition time, and data processing speed. In this article, we present a new deep learning (DL) framework combining multibranch convolutional neural network (CNN) and recursive transformer (RT), termed ULM-MbCNRT, that is capable of reconstructing a super-resolution (SR) image directly from a temporal mean low-resolution image generated by averaging much fewer raw US frames, i.e., implement an ultrafast ULM imaging. To evaluate the performance of ULM-MbCNRT, a series of numerical simulations and in vivo experiments are carried out. Numerical simulation results indicate that ULM-MbCNRT achieves high-quality ULM imaging with ~10-fold reduction in data acquisition time and ~130-fold reduction in computation time compared to the previous DL method (e.g., the modified subpixel CNN, ULM-mSPCN). For the in vivo experiments, when comparing to the ULM-mSPCN, ULM-MbCNRT allows ~37-fold reduction in data acquisition time (~0.8 s) and ~2134-fold reduction in computation time (~0.87 s) without sacrificing spatial resolution. It implies that ultrafast ULM imaging holds promise for observing rapid biological activity in vivo, potentially improving the diagnosis and monitoring of clinical conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Explorer Program of Shanghai
- Natural Science Foundation of Shanghai
- Medical Engineering Fund of Fudan University
Zitieren
APA
Zhang, G., Gu, W., Yue, Y., Tang, M. X., Luo, J., Liu, X., & Ta, D. (2024). ULM-MbCNRT: In Vivo Ultrafast Ultrasound Localization Microscopy by Combining Multibranch CNN and Recursive Transformer. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3388102
Vancouver
Zhang G, Gu W, Yue Y, Tang MX, Luo J, Liu X, et al. ULM-MbCNRT: In Vivo Ultrafast Ultrasound Localization Microscopy by Combining Multibranch CNN and Recursive Transformer. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3388102
BibTeX
@article{Zhang2024,
author = {Zhang, Gaobo and Gu, Wenting and Yue, Yaoting and Tang, Meng-Xing and Luo, Jianwen and Liu, Xin and Ta, Dean},
title = {ULM-MbCNRT: In Vivo Ultrafast Ultrasound Localization Microscopy by Combining Multibranch CNN and Recursive Transformer},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3388102}
}
EUVIMED