EUVIMEDEUVIMED entdecken
Crossref

A Tracking Prior to Localization Workflow for Ultrasound Localization Microscopy

Alexis Leconte, Jonathan Poree, Brice Rauby, Alice Wu, Nin Ghigo, Paul Xing, Stephen Lee, Chloe Bourquin, Gerardo Ramos-Palacios, Abbas F Sadikot, Jean Provost

IEEE Transactions on Medical Imaging · 2025-02 · 44 (2) · 698-710

DOI: 10.1109/tmi.2024.3456676 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-02. Verfasst von Alexis Leconte und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Microscopy, Acoustic. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Institute for Data Valorization, Canada Foundation for Innovation, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound Localization Microscopy (ULM) has proven effective in resolving microvascular structures and local mean velocities at sub-diffraction-limited scales, offering high-resolution imaging capabilities. Dynamic ULM (DULM) enables the creation of angiography or velocity movies throughout cardiac cycles. Currently, these techniques rely on a Localization-and-Tracking (LAT) workflow consisting in detecting microbubbles (MB) in the frames before pairing them to generate tracks. While conventional LAT methods perform well at low concentrations, they suffer from longer acquisition times and degraded localization and tracking accuracy at higher concentrations, leading to biased angiogram reconstruction and velocity estimation. In this study, we propose a novel approach to address these challenges by reversing the current workflow. The proposed method, Tracking-and-Localization (TAL), relies on first tracking the MB and then performing localization. Through comprehensive benchmarking using both in silico and in vivo experiments and employing various metrics to quantify ULM angiography and velocity maps, we demonstrate that the TAL method consistently outperforms the reference LAT workflow. Moreover, when applied to DULM, TAL successfully extracts velocity variations along the cardiac cycle with improved repeatability. The findings of this work highlight the effectiveness of the TAL approach in overcoming the limitations of conventional LAT methods, providing enhanced ULM angiography and velocity imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedMicroscopy, AcousticAnimalsMicrobubblesWorkflowAlgorithmsAngiographyHeart

Förderung

  • Institute for Data Valorization
  • Canada Foundation for Innovation
  • Canadian Institutes of Health Research
  • New Frontiers in Research Fund
  • Natural Sciences and Engineering Research Council of Canada
  • Calcul Québec (calculquebec.ca) and the Digital Research Alliance of Canada
  • TransMedTech Institute
  • Quebec Bio-Imaging Network

Zitieren

APA

Leconte, A., Poree, J., Rauby, B., Wu, A., Ghigo, N., Xing, P., Lee, S., Bourquin, C., Ramos-Palacios, G., Sadikot, A. F., & Provost, J. (2025). A Tracking Prior to Localization Workflow for Ultrasound Localization Microscopy. IEEE Transactions on Medical Imaging, 44(2), 698-710. https://doi.org/10.1109/tmi.2024.3456676

Vancouver

Leconte A, Poree J, Rauby B, Wu A, Ghigo N, Xing P, et al. A Tracking Prior to Localization Workflow for Ultrasound Localization Microscopy. IEEE Transactions on Medical Imaging. 2025;44(2):698-710. doi:10.1109/tmi.2024.3456676

BibTeX
@article{Leconte2025,
  author = {Leconte, Alexis and Poree, Jonathan and Rauby, Brice and Wu, Alice and Ghigo, Nin and Xing, Paul and Lee, Stephen and Bourquin, Chloe and Ramos-Palacios, Gerardo and Sadikot, Abbas F and Provost, Jean},
  title = {A Tracking Prior to Localization Workflow for Ultrasound Localization Microscopy},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2025},
  volume = {44},
  number = {2},
  pages = {698--710},
  doi = {10.1109/tmi.2024.3456676}
}
Kostenlos starten →