Effects of Size Polydispersity and Dense Media on Quantitative Ultrasound Estimates

Olivier Lombard, Emilie Franceschini

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024

DOI: 10.1109/tuffc.2024.3379293 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Olivier Lombard und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Ultrasonography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: French National Research Agency, Excellence Initiative of Aix-Marseille University—A*MIDEX.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative ultrasound (QUS) techniques based on the backscatter coefficient (BSC) aim to characterize the scattering properties of biological tissues. A scattering model is fit to the measured BSC, and the fitted QUS parameters can provide local tissue microstructure, namely, scatterer size and acoustic concentration. However, these techniques may fail to provide a correct description of tissue microstructure when the medium is polydisperse and/or dense. The objective of this study is to investigate the effects of scatterer size polydispersity in sparse or dense media on the QUS estimates. Four scattering models (i.e., the monodisperse and polydisperse sparse models, and the monodisperse and polydisperse concentrated models based on the structure factor) are compared to assess their accuracy and reliability in quantifying the QUS estimates. Simulations are conducted with different scatterer size distributions for sparse, moderately dense, and dense media (volume fractions of 1%, 20%, and 73%, respectively). The QUS parameters are estimated by using model-based inverse methods at different center frequencies between 8 and 50 MHz. Experimental data are also analyzed using colon adenocarcinoma HT29 cell pellet biophantoms to further validate the results obtained from simulations at the volume fraction of 73%. Our findings reveal that the choice of scattering model has a significant impact on the accuracy of QUS estimates. For sufficiently high frequencies and dense media, the polydisperse concentrated model outperforms the other models and enables more accurate quantification. Furthermore, our results contribute to advancing our understanding of the complexities associated with scatterer size polydispersity and dense media in spectral-based QUS techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UltrasonographyHumansPhantoms, ImagingImage Processing, Computer-AssistedComputer SimulationAlgorithmsScattering, Radiation

Förderung

  • French National Research Agency
  • Excellence Initiative of Aix-Marseille University—A*MIDEX

Zitieren

APA

Lombard, O., & Franceschini, E. (2024). Effects of Size Polydispersity and Dense Media on Quantitative Ultrasound Estimates. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3379293

Vancouver

Lombard O, Franceschini E. Effects of Size Polydispersity and Dense Media on Quantitative Ultrasound Estimates. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3379293

BibTeX
@article{Lombard2024,
  author = {Lombard, Olivier and Franceschini, Emilie},
  title = {Effects of Size Polydispersity and Dense Media on Quantitative Ultrasound Estimates},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2024},
  doi = {10.1109/tuffc.2024.3379293}
}
Kostenlos starten →