EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Volumetric Ultrasound Localization Microscopy With Diverging Cylindrical Waves

Antoine Coudert, Arthur Chavignon, Louise Denis, Olivier Couture

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024

DOI: 10.1109/tuffc.2024.3375896 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Antoine Coudert und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Microscopy. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council (ERC) through the H2020 Program within the ERC Consolidator Grants.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcranial ultrasound plays a limited role in neuroradiology due to its lack of resolution, planar imaging, and user dependency. By breaching the diffraction limit using injected microbubbles, volumetric ultrasound localization microscopy (ULM) could help alleviate those issues. However, performing 3-D ultrasound imaging at a high frame rate with sufficient signal-to-noise ratio (SNR) to track individual microbubbles through the skull remains a challenge, especially with a portable scanner. In this study, we describe a ULM sequence suitable for volumetric transcranial imaging exploiting cylindrical emissions on multiplexed matrix probes, through simulations, hydrophone measurements, and flow phantoms. This geometry leads to a doubling of the peak acoustic pressure, up to 400 kPa, with respect to spherical emission and improved volume rate, up to 180 Hz. Cylindrical emissions also improve the ULM saturation rate by 60% through a skull phantom. The assessment of microbubble velocity was also improved from a 33% error in the average flow measured with spherical waves to a 5% error with cylindrical waves. Conversely, we demonstrate the detrimental impacts of cylindrical waves toward the field of view and isotropic sensitivity. Nevertheless, due to its enhanced SNR and 3-D nature, such a cylindrical volumetric sequence could be beneficial for ULM as a diagnostic tool in humans, especially when portability is a necessity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMicroscopyPhantoms, ImagingMicrobubblesSkullSignal-To-Noise RatioHumansUltrasonography

Förderung

  • European Research Council (ERC) through the H2020 Program within the ERC Consolidator Grants

Zitieren

APA

Coudert, A., Chavignon, A., Denis, L., & Couture, O. (2024). Volumetric Ultrasound Localization Microscopy With Diverging Cylindrical Waves. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3375896

Vancouver

Coudert A, Chavignon A, Denis L, Couture O. Volumetric Ultrasound Localization Microscopy With Diverging Cylindrical Waves. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3375896

BibTeX
@article{Coudert2024,
  author = {Coudert, Antoine and Chavignon, Arthur and Denis, Louise and Couture, Olivier},
  title = {Volumetric Ultrasound Localization Microscopy With Diverging Cylindrical Waves},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2024},
  doi = {10.1109/tuffc.2024.3375896}
}
Kostenlos starten →