Waveform-Specific Performance of Deep Learning-Based Super-Resolution for Ultrasound Contrast Imaging
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2025
DOI: 10.1109/tuffc.2025.3537298 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2025. Verfasst von Rienk Zorgdrager und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Deep Learning, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: HORIZON.1.1 Program of European Research Council through the Super-FALCON, 4TU Precision Medicine program supported by High Tech for a Sustainable Future, a framework commissioned by the four Universities of Technology of the Netherla….
Abstract (Originalsprache)
Resolving arterial flows is essential for understanding cardiovascular pathologies, improving diagnosis, and monitoring patient condition. Ultrasound contrast imaging uses microbubbles to enhance the scattering of the blood pool, allowing for real-time visualization of blood flow. Recent developments in vector flow imaging further expand the imaging capabilities of ultrasound by temporally resolving fast arterial flow. The next obstacle to overcome is the lack of spatial resolution. Super-resolved ultrasound images can be obtained by deconvolving radiofrequency (RF) signals before beamforming, breaking the link between resolution and pulse duration. Convolutional neural networks (CNNs) can be trained to locally estimate the deconvolution kernel and consequently super-localize the microbubbles directly within the RF signal. However, microbubble contrast is highly nonlinear, and the potential of CNNs in microbubble localization has not yet been fully exploited. Assessing deep learning-based deconvolution performance for nontrivial imaging pulses is therefore essential for successful translation to a practical setting, where the signal-to-noise ratio (SNR) is limited, and transmission schemes should comply with safety guidelines. In this study, we train CNNs to deconvolve RF signals and localize the microbubbles driven by harmonic pulses, chirps, or delay-encoded pulse trains. Furthermore, we discuss potential hurdles for in vitro and in vivo super-resolution by presenting preliminary experimental results. We find that, whereas the CNNs can accurately localize microbubbles for all pulses, a short imaging pulse offers the best performance in noise-free conditions. However, chirps offer a comparable performance without noise, but they are more robust to noise and outperform all other pulses in low-SNR conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- HORIZON.1.1 Program of European Research Council through the Super-FALCON
- 4TU Precision Medicine program supported by High Tech for a Sustainable Future, a framework commissioned by the four Universities of Technology of the Netherla…
Zitieren
APA
Zorgdrager, R., Blanken, N., Wolterink, J. M., Versluis, M., & Lajoinie, G. (2025). Waveform-Specific Performance of Deep Learning-Based Super-Resolution for Ultrasound Contrast Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2025.3537298
Vancouver
Zorgdrager R, Blanken N, Wolterink JM, Versluis M, Lajoinie G. Waveform-Specific Performance of Deep Learning-Based Super-Resolution for Ultrasound Contrast Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2025. doi:10.1109/tuffc.2025.3537298
BibTeX
@article{Zorgdrager2025,
author = {Zorgdrager, Rienk and Blanken, Nathan and Wolterink, Jelmer M and Versluis, Michel and Lajoinie, Guillaume},
title = {Waveform-Specific Performance of Deep Learning-Based Super-Resolution for Ultrasound Contrast Imaging},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2025},
doi = {10.1109/tuffc.2025.3537298}
}