Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024-04 · 71 (4) · 448-458
DOI: 10.1109/tuffc.2024.3366540 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024-04. Verfasst von Zhijie Dong und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Defense (DoD) through the Breast Cancer Research Program.
Abstract (Originalsprache)
Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide a robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view (FOV). In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Department of Defense (DoD) through the Breast Cancer Research Program
Zitieren
APA
Dong, Z., Lok, U. W., Lowerison, M. R., Huang, C., Chen, S., & Song, P. (2024). Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 71(4), 448-458. https://doi.org/10.1109/tuffc.2024.3366540
Vancouver
Dong Z, Lok UW, Lowerison MR, Huang C, Chen S, Song P. Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024;71(4):448-458. doi:10.1109/tuffc.2024.3366540
BibTeX
@article{Dong2024,
author = {Dong, Zhijie and Lok, U-Wai and Lowerison, Matthew R and Huang, Chengwu and Chen, Shigao and Song, Pengfei},
title = {Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
volume = {71},
number = {4},
pages = {448--458},
doi = {10.1109/tuffc.2024.3366540}
}
EUVIMED