Prescribed-Time Mitigation of False Data Attacks in Microgrid Load Frequency Control
IEEE Transactions on Smart Grid · 2025-07 · 16 (4) · 3256-3268
DOI: 10.1109/tsg.2025.3557207 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Smart Grid, 2025-07. Verfasst von Said I. Abouzeid und 4 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Key Research and Development Plan Programs of China, Egyptian Science, Technology and Innovation Funding Authority.
Abstract (Originalsprache)
Microgrid load frequency control (LFC) operation relies extensively on cyber networks which significantly increases their susceptibility to false data injection attacks (FDIAs) that can undermine microgrid’s stability. This paper proposes a multi-layer control framework that efficiently detects and mitigates false data injected in the actuator and measurements of the LFC. Firstly, an FDIAs detection layer based on an unknown input observer (UIO) utilizing an adaptive threshold has been proposed. An adaptive threshold aims to enhance detection sensitivity and reduce false alarms by distinguishing between actual attacks and temporal discrepancies in observer error caused by internal disturbances. Secondly, to ensure timely and accurate mitigation of FDIAs, an estimation layer utilizing a prescribed-time unknown input observer (PTUIO) has been designed. PTUIO is designed to be robust against unknown inputs and parameter uncertainty. The PTUIO employs periodic time-delayed output to estimate system states and FDIAs within a predefined time. Afterward, a two-layer robust and resilient LFC system was developed. The first layer ensures the rejection of unknown inputs, including load/generation disturbances and FDIAs based on PTUIO estimations. The second layer incorporates robust state feedback control, which stabilizes the microgrid and accurately tracks the frequency reference. The effectiveness of the proposed control system is confirmed through multiple scenarios by simulations and Hardware-in-the-loop (HIL), demonstrating its robustness and reliability in addressing challenges associated with internal disturbances, and FDIAs within the microgrid.
Förderung
- National Key Research and Development Plan Programs of China
- Egyptian Science, Technology and Innovation Funding Authority
Zitieren
APA
Abouzeid, S. I., Chen, Y., Zaery, M., Amrr, S. M., & Abdelhameed, E. H. (2025). Prescribed-Time Mitigation of False Data Attacks in Microgrid Load Frequency Control. IEEE Transactions on Smart Grid, 16(4), 3256-3268. https://doi.org/10.1109/tsg.2025.3557207
Vancouver
Abouzeid SI, Chen Y, Zaery M, Amrr SM, Abdelhameed EH. Prescribed-Time Mitigation of False Data Attacks in Microgrid Load Frequency Control. IEEE Transactions on Smart Grid. 2025;16(4):3256-3268. doi:10.1109/tsg.2025.3557207
BibTeX
@article{Abouzeid2025,
author = {Abouzeid, Said I. and Chen, Yong and Zaery, Mohamed and Amrr, Syed Muhammad and Abdelhameed, Esam H.},
title = {Prescribed-Time Mitigation of False Data Attacks in Microgrid Load Frequency Control},
journal = {IEEE Transactions on Smart Grid},
year = {2025},
volume = {16},
number = {4},
pages = {3256--3268},
doi = {10.1109/tsg.2025.3557207}
}
EUVIMED