Dual-Input Dynamic Convolution for Positron Range Correction in PET Image Reconstruction
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-07 · 10 (6) · 888-898
DOI: 10.1109/trpms.2025.3647264 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-07. Verfasst von Youness Mellak und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: French Government, Labex CominLabs Excellence Laboratory and managed by the French National Research Agency, Investing for the Future Program.
Abstract (Originalsprache)
Positron range (PR) blurring degrades positron emission tomography (PET) image resolution, particularly for high-energy emitters like 68Ga. We introduce Dual-Input Dynamic Convolution (DDConv), a novel computationally efficient approach trained with voxel-specific PR point spread functions from Monte Carlo (MC) simulations and designed to be utilized within an iterative reconstruction algorithm to perform PR correction (PRC). By dynamically inferring local blurring kernels through a trained convolutional neural network (CNN), DDConv captures complex tissue interfaces more accurately than prior methods. Additionally, it also computes the transpose operator, ensuring consistency within iterative PET reconstruction. Comparisons with a state-of-the-art, tissue-dependent correction confirm the advantages of DDConv in recovering higher-resolution details in heterogeneous regions, including bone–soft tissue and lung–soft tissue boundaries. Experiments across digital phantoms and MC-simulated data show that DDConv offers near-MC accuracy and outperforms the state-of-the-art technique, namely spatially-variant and tissue-dependent (SVTD), especially in areas with complex material interfaces. Results from real phantom experiments further confirm DDConv’s robustness and practical applicability: while both DDConv and SVTD performed similarly in homogeneous soft-tissue regions, DDConv provided more accurate activity recovery and sharper delineation at heterogeneous lung–soft tissue interfaces. Our code available at.
Förderung
- French Government
- Labex CominLabs Excellence Laboratory and managed by the French National Research Agency
- Investing for the Future Program
- ANR
Zitieren
APA
Mellak, Y., Bousse, A., Merlin, T., Émond, É., Hakulinen, M., & Visvikis, D. (2026). Dual-Input Dynamic Convolution for Positron Range Correction in PET Image Reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(6), 888-898. https://doi.org/10.1109/trpms.2025.3647264
Vancouver
Mellak Y, Bousse A, Merlin T, Émond É, Hakulinen M, Visvikis D. Dual-Input Dynamic Convolution for Positron Range Correction in PET Image Reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(6):888-898. doi:10.1109/trpms.2025.3647264
BibTeX
@article{Mellak2026,
author = {Mellak, Youness and Bousse, Alexandre and Merlin, Thibaut and Émond, Élise and Hakulinen, Mikko and Visvikis, Dimitris},
title = {Dual-Input Dynamic Convolution for Positron Range Correction in PET Image Reconstruction},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {6},
pages = {888--898},
doi = {10.1109/trpms.2025.3647264}
}
EUVIMED