Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions
IEEE Transactions on Radiation and Plasma Medical Sciences · 2026-03 · 10 (3) · 436-443
DOI: 10.1109/trpms.2025.3591229 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2026-03. Verfasst von M. Carmen Jiménez-Ramos und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications.
Zitieren
APA
Jiménez-Ramos, M. C., Torres-Muñoz, C., García-López, J., Barroso-Molina, D., Guardiola, C., & Fleta, C. (2026). Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions. IEEE Transactions on Radiation and Plasma Medical Sciences, 10(3), 436-443. https://doi.org/10.1109/trpms.2025.3591229
Vancouver
Jiménez-Ramos MC, Torres-Muñoz C, García-López J, Barroso-Molina D, Guardiola C, Fleta C. Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions. IEEE Transactions on Radiation and Plasma Medical Sciences. 2026;10(3):436-443. doi:10.1109/trpms.2025.3591229
BibTeX
@article{JimnezRamos2026,
author = {Jiménez-Ramos, M. Carmen and Torres-Muñoz, Carmen and García-López, Javier and Barroso-Molina, Diego and Guardiola, Consuelo and Fleta, Celeste},
title = {Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions},
journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
year = {2026},
volume = {10},
number = {3},
pages = {436--443},
doi = {10.1109/trpms.2025.3591229}
}
EUVIMED