EUVIMEDEUVIMED entdecken
Open Access

Timing Performance With Broadcom Metal Trench Silicon Photomultipliers

Seungeun Lee, Woon-Seng Choong, Ryan Heller, Joshua W Cates

IEEE Transactions on Radiation and Plasma Medical Sciences · 2025-04 · 9 (4) · 406-411

DOI: 10.1109/trpms.2024.3518479 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Radiation and Plasma Medical Sciences, 2025-04. Verfasst von Seungeun Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Single photon time resolution (SPTR), photon detection efficiency (PDE), and correlated noise rate are important performance characteristics of modern silicon photomultipliers (SiPMs) in consideration of advances in time-of-flight positron emission tomography (TOF-PET). Commercially available Broadcom near-ultra-violet metal-trench (NUV-MT) SiPMs feature metal-filled trench technology to suppress optical crosstalk. We investigated the achievable SPTR and coincidence time resolution (CTR) of NUV-MT SiPMs with various sizes and scintillation crystals, employing low-noise high-frequency readout electronics. The achievable intrinsic SPTRs of 2×2, 4×4, and 6×6 mm2 devices were estimated using a picosecond-pulse laser setup. 2- and 4-mm SiPMs were coupled with 2×2×3 mm3 and 3×3×20 mm3 LGSO and BGO crystals to assess achievable CTRs. The intrinsic SPTRs of 2-, 4-, and 6-mm SiPMs biased with 48 V were estimated to be 45, 55, and 137 ps in full-width at half-maximum (FWHM), respectively. The detector comprised a 2-mm SiPM and a 2×2×3 mm3 BGO achieved 111 ps CTR FWHM. The results demonstrated a significant influence of superior SPTR of 2-mm SiPM for the Cherenkov event portion compared to scintillation-based events. The suppressed noise of NUV-MT enabled stable operation at high bias voltage, offering excellent SPTR and PDE for breakthroughs in the timing resolution of TOF-PET detectors.

Schlagwörter

Stichwörter der Autor:innen

coincidence time resolutionhigh-frequency readoutsilicon photomultiplierssingle photon time resolutiontime-of-flight PET

Autor:innen und Institutionen

  • Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 USA.

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health

Zitieren

APA

Lee, S., Choong, W. S., Heller, R., & Cates, J. W. (2025). Timing Performance With Broadcom Metal Trench Silicon Photomultipliers. IEEE Transactions on Radiation and Plasma Medical Sciences, 9(4), 406-411. https://doi.org/10.1109/trpms.2024.3518479

Vancouver

Lee S, Choong WS, Heller R, Cates JW. Timing Performance With Broadcom Metal Trench Silicon Photomultipliers. IEEE Transactions on Radiation and Plasma Medical Sciences. 2025;9(4):406-411. doi:10.1109/trpms.2024.3518479

BibTeX
@article{Lee2025,
  author = {Lee, Seungeun and Choong, Woon-Seng and Heller, Ryan and Cates, Joshua W},
  title = {Timing Performance With Broadcom Metal Trench Silicon Photomultipliers},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2025},
  volume = {9},
  number = {4},
  pages = {406--411},
  doi = {10.1109/trpms.2024.3518479}
}