Radiation damage studies of silicon photomultipliers for the CMS MIP Timing Detector
Journal of Instrumentation · 01.07.2026 · 21 (07) · C07005
DOI: 10.1088/1748-0221/21/07/c07005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Instrumentation, online erschienen am 02.07.2026. Verfasst von Y. Musienko und 3 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Recently developed 15 um, 20 um, 25 um and 30 um cell size Hamamatsu Silicon Photomultipliers (SiPMs) were irradiated with reactor neutrons at JSI (Ljubljana) up to 2×10 14 n/cm 2 (1 MeV equivalent). The parameters of new and irradiated SiPMs were studied using pulsed light illumination. The effects of the neutron radiation on breakdown voltage, signal amplitude, dark current and noise for these devices are shown and discussed.
Zitieren
APA
Musienko, Y., Heering, A., Karneyeu, A., & Wayne, M. (2026). Radiation damage studies of silicon photomultipliers for the CMS MIP Timing Detector. Journal of Instrumentation, 21(07), C07005. https://doi.org/10.1088/1748-0221/21/07/c07005
Vancouver
Musienko Y, Heering A, Karneyeu A, Wayne M. Radiation damage studies of silicon photomultipliers for the CMS MIP Timing Detector. Journal of Instrumentation. 2026;21(07):C07005. doi:10.1088/1748-0221/21/07/c07005
BibTeX
@article{Musienko2026,
author = {Musienko, Y. and Heering, A. and Karneyeu, A. and Wayne, M.},
title = {Radiation damage studies of silicon photomultipliers for the CMS MIP Timing Detector},
journal = {Journal of Instrumentation},
year = {2026},
volume = {21},
number = {07},
pages = {C07005},
doi = {10.1088/1748-0221/21/07/c07005}
}
EUVIMED