A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring

Hanbo Zheng, Shiqi Xu, Jinheng Li, Fang Gao, Zhimei Cui

IEEE Transactions on Power Delivery · 2025-04 · 40 (2) · 810-821

DOI: 10.1109/tpwrd.2024.3522808 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Power Delivery, 2025-04. Verfasst von Hanbo Zheng und 4 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Science Fund for Distinguished Young Scholars.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the high-voltage environment of substations, due to the lack of effective monitoring methods, personnel may fail to maintain a safe distance from the equipment due to subjective factors, leading to electric shock accidents. To more effectively reduce the occurrence of such accidents, this paper proposes a monocular vision-based method for monitoring the safety distance between personnel and live equipment. Firstly, this paper makes lightweight improvements to the YOLOv8 (You Only Look Once) keypoint detection model by introducing the proposed dense feature fusion (DFF) module and adaptive channel cross (ACC) module into the backbone and neck, respectively, and replacing the network's original path aggregation network (PAN) structure with the bi-directional feature pyramid network (BiFPN) structure. Subsequently, based on the principles of camera imaging and perspective geometry, this paper calculates the mapping relationship between two-dimensional pixel coordinates and three-dimensional world coordinates. Finally, based on the detected keypoints and the obtained mapping relationship, the distance between personnel and live equipment is monitored. Experiments conducted in a substation scenario show that the improved keypoint detection model increases AP from 0.718 to 0.771, reduces parameters from 3.09M to 2.10M, and lowers FLOPs from 8.48G to 7.01G, and the maximum distance measurement error is only 3.778%.

Förderung

  • National Natural Science Foundation of China
  • Guangxi Science Fund for Distinguished Young Scholars

Zitieren

APA

Zheng, H., Xu, S., Li, J., Gao, F., & Cui, Z. (2025). A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring. IEEE Transactions on Power Delivery, 40(2), 810-821. https://doi.org/10.1109/tpwrd.2024.3522808

Vancouver

Zheng H, Xu S, Li J, Gao F, Cui Z. A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring. IEEE Transactions on Power Delivery. 2025;40(2):810-821. doi:10.1109/tpwrd.2024.3522808

BibTeX
@article{Zheng2025,
  author = {Zheng, Hanbo and Xu, Shiqi and Li, Jinheng and Gao, Fang and Cui, Zhimei},
  title = {A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring},
  journal = {IEEE Transactions on Power Delivery},
  year = {2025},
  volume = {40},
  number = {2},
  pages = {810--821},
  doi = {10.1109/tpwrd.2024.3522808}
}
Kostenlos starten →