Robust Safety Distance Monitoring in Live Substation Operations via Mask‐Constrained Stereo Vision

Jiahao Wang, Bo Wang, Fei Liu, Hengrui Ma, Fuqi Ma, Zesong Yin

IET Generation, Transmission & Distribution · 2026-01 · 20 (1)

DOI: 10.1049/gtd2.70353 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Generation, Transmission & Distribution, online erschienen am 18.06.2026. Verfasst von Jiahao Wang und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Safety distance monitoring is a critical requirement for live substation operations, where inaccurate distance perception may lead to severe safety hazards. Existing vision‐based approaches commonly estimate distances using single representative points, such as detection box centres, which are sensitive to irregular object geometries, depth noise, and threshold‐induced decision instability in complex operational environments. This paper proposes a vision‐based safety distance monitoring framework that integrates image segmentation and binocular vision for robust spatial distance perception. Operational elements are modelled as three‐dimensional regions rather than isolated points, and a mask‐constrained region‐to‐region distance formulation is introduced by combining candidate point selection with robust statistical aggregation. An enhanced segmentation‐based perception module is adopted to improve planar localisation accuracy under scale variation and deformation, while a lightweight pruning strategy enables real‐time deployment. Experimental results on live substation operation scenarios show that the proposed method reduces the distance estimation error from 2.52 m to 1.04 m in MAE and from 3.48 m to 1.68 m in RMSE while improving the safety decision correctness from 88.6% to 92.4% and reducing both false alarms and missed warnings near safety thresholds.

Zitieren

APA

Wang, J., Wang, B., Liu, F., Ma, H., Ma, F., & Yin, Z. (2026). Robust Safety Distance Monitoring in Live Substation Operations via Mask‐Constrained Stereo Vision. IET Generation, Transmission & Distribution, 20(1). https://doi.org/10.1049/gtd2.70353

Vancouver

Wang J, Wang B, Liu F, Ma H, Ma F, Yin Z. Robust Safety Distance Monitoring in Live Substation Operations via Mask‐Constrained Stereo Vision. IET Generation, Transmission & Distribution. 2026;20(1). doi:10.1049/gtd2.70353

BibTeX
@article{Wang2026,
  author = {Wang, Jiahao and Wang, Bo and Liu, Fei and Ma, Hengrui and Ma, Fuqi and Yin, Zesong},
  title = {Robust Safety Distance Monitoring in Live Substation Operations via Mask‐Constrained Stereo Vision},
  journal = {IET Generation, Transmission & Distribution},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/gtd2.70353}
}
Kostenlos starten →