The Peak Stress Measurement of Discharge Electromagnetic Coils Based on FBG
IEEE Transactions on Plasma Science · 2026-08 · 54 (8) · 4092-4100
DOI: 10.1109/tps.2026.3708137 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Plasma Science, 2026-08. Verfasst von Yadong Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Special Funds for Basic Scientific Research Business Funds of Central Universities.
Abstract (Originalsprache)
The electromagnetic coil is the core component of electromagnetic launch systems and is widely used in both military and civilian applications. It typically operates under extreme conditions such as high current, a significant temperature rise, and strong mechanical stress. Electromagnetic force is a primary cause of coil aging and failure. However, due to the sealed structure and harsh operating environment of the coil, existing research on electromagnetic force mainly relies on simulations, with limited experimental validation. In this study, a coil launch experiment platform was established, and the pulsed stress on the coil conductor was measured using fiber Bragg grating (FBG) sensors. A 2-D axisymmetric, electromagnetic-structural coupled model was developed to analyze the stress distribution of the coil under no-load and locked conditions. Multiple measuring points were tested, and the results showed consistent trends. For clarity, the results at measuring point 1 are presented here: under the locked condition, the peak stresses reached 0.49 and 1.95 MPa at 1000 and 2000 V, respectively. With FBG sensors embedded on the conductor surface to monitor stress, coupled simulations revealed that the negligible $0.09~^{\circ }$ C temperature rise at the measurement point 1 during the rising edge produces a thermal strain of merely $0.28~\mu \varepsilon $ , which falls strictly below the sensor’s measurement resolution and thereby proves that the recorded wavelength variation is essentially induced by mechanical stress. Comparison between the experimental and simulation results showed an error of less than 10% under various discharge conditions, confirming the feasibility and effectiveness of the proposed method for stress measurement in electromagnetic coils under high-electromagnetic interference environments.
Förderung
- National Natural Science Foundation of China
- Special Funds for Basic Scientific Research Business Funds of Central Universities
Zitieren
APA
Zhang, Y., Feng, J., Zhu, M., & Dong, S. (2026). The Peak Stress Measurement of Discharge Electromagnetic Coils Based on FBG. IEEE Transactions on Plasma Science, 54(8), 4092-4100. https://doi.org/10.1109/tps.2026.3708137
Vancouver
Zhang Y, Feng J, Zhu M, Dong S. The Peak Stress Measurement of Discharge Electromagnetic Coils Based on FBG. IEEE Transactions on Plasma Science. 2026;54(8):4092-4100. doi:10.1109/tps.2026.3708137
BibTeX
@article{Zhang2026,
author = {Zhang, Yadong and Feng, Jiahao and Zhu, Mingzhi and Dong, Senlin},
title = {The Peak Stress Measurement of Discharge Electromagnetic Coils Based on FBG},
journal = {IEEE Transactions on Plasma Science},
year = {2026},
volume = {54},
number = {8},
pages = {4092--4100},
doi = {10.1109/tps.2026.3708137}
}
EUVIMED