How to Consider SEEs When Designing a SiGe Low-Noise Amplifier—An Overview
IEEE Transactions on Nuclear Science · 2024-08 · 71 (8) · 1663-1674
DOI: 10.1109/tns.2024.3371329 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Nuclear Science, 2024-08. Verfasst von Jeffrey W. Teng und 4 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 68 Literaturangaben.
Abstract (Originalsprache)
The application of radiation-hardening by design (RHBD) to the low-noise amplifier (LNA) in an RF communications receiver has promise for improving data fidelity in applications subject to single-event effects (SEEs). In order to overcome the challenges of empirically modeling single-event transient (SET) propagation in RF receivers, calibrated technology computer-aided design (TCAD) is used to perform mixed-mode simulations and identify viable RHBD approaches for SiGe cascode LNAs. Example results at X-band (8–12 GHz) are used to demonstrate these approaches. Finally, the findings in the present work are organized into a proposed radiation-hardening design flow to aid circuit and system engineers who wish to consider single-event-upset (SEU) rates in the performance of their LNAs.
Zitieren
APA
Teng, J. W., Nergui, D., Mensah, Y. A., Ildefonso, A., & Cressler, J. D. (2024). How to Consider SEEs When Designing a SiGe Low-Noise Amplifier—An Overview. IEEE Transactions on Nuclear Science, 71(8), 1663-1674. https://doi.org/10.1109/tns.2024.3371329
Vancouver
Teng JW, Nergui D, Mensah YA, Ildefonso A, Cressler JD. How to Consider SEEs When Designing a SiGe Low-Noise Amplifier—An Overview. IEEE Transactions on Nuclear Science. 2024;71(8):1663-1674. doi:10.1109/tns.2024.3371329
BibTeX
@article{Teng2024,
author = {Teng, Jeffrey W. and Nergui, Delgermaa and Mensah, Yaw A. and Ildefonso, Adrian and Cressler, John D.},
title = {How to Consider SEEs When Designing a SiGe Low-Noise Amplifier—An Overview},
journal = {IEEE Transactions on Nuclear Science},
year = {2024},
volume = {71},
number = {8},
pages = {1663--1674},
doi = {10.1109/tns.2024.3371329}
}