Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection
IEEE Transactions on NanoBioscience · 2023-10 · 22 (4) · 897-903
DOI: 10.1109/tnb.2023.3246535 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on NanoBioscience, 2023-10. Verfasst von Archana Yadav und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Biosensing Techniques. Die Arbeit wurde bisher 98-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Department of Atomic Energy (DAE), Government of India, under Raja Ramanna Fellowship.
Abstract (Originalsprache)
The present study introduces a highly sensitive bimetallic SPR biosensor based on metal nitride for efficient urine glucose detection. Using a BK-7 prism, Au (25 nm), Ag (25nm), AlN (15 nm), and a biosample (urine) layer, the proposed sensor comprises of five layers. The selection of the sequence and dimensions of both metal layers is based on their performance in a number of case studies including both monometallic and bimetallic layers. After optimizing the bimetallic layer as Au (25 nm) - Ag (25 nm), various nitride layers were used to further increase the sensitivity by utilizing the synergistic effect of the bimetallic and metal nitride layers through case studies of several urine samples, ranging from nondiabetic to severely diabetic patients. AlN is determined to be the best suited material, and its thickness is optimized to 15 nanometers. The performance of the structure has been evaluated using a visible wavelength, i.e., λ = 633 nm, in order to increase sensitivity while providing room for low-cost prototyping. With the layer parameters optimized, a significant sensitivity of 411°/RIU (Refractive Index Unit) and figure of merit (FoM) of 105.38 /RIU has been achieved. The computed resolution of the proposed sensor is 4.17e-06. This study's findings have also been compared to some recently reported results. The proposed structure would be useful for detecting glucose concentrations, with a rapid response as measured by a substantial shift in resonance angle in SPR curves.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Department of Atomic Energy (DAE), Government of India, under Raja Ramanna Fellowship
Zitieren
APA
Yadav, A., Kumar, A., Sharan, P., & Mishra, M. (2023). Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection. IEEE Transactions on NanoBioscience, 22(4), 897-903. https://doi.org/10.1109/tnb.2023.3246535
Vancouver
Yadav A, Kumar A, Sharan P, Mishra M. Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection. IEEE Transactions on NanoBioscience. 2023;22(4):897-903. doi:10.1109/tnb.2023.3246535
BibTeX
@article{Yadav2023,
author = {Yadav, Archana and Kumar, Anil and Sharan, Preeta and Mishra, Madhusudan},
title = {Highly Sensitive Bimetallic-Metal Nitride SPR Biosensor for Urine Glucose Detection},
journal = {IEEE Transactions on NanoBioscience},
year = {2023},
volume = {22},
number = {4},
pages = {897--903},
doi = {10.1109/tnb.2023.3246535}
}
EUVIMED