EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood

Lei Zhao, Hua Yang, Tangyou Sun iD, Qianju Song, Zao Yi iD, Yougen Yi

Sensors · 2025

DOI: 10.3390/s25092647 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Lei Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Joint Laboratory for Extreme Conditions Matter Properties, The State Key Laboratory of Environment-Friendly Energy Materials, School of Mathematics a…. Hauptthemen laut MEDLINE: Blood Glucose, Biosensing Techniques, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research introduces a biosensor utilizing surface plasmon resonance in a photonic crystal fiber (PCF) configuration. PCF uses fused silica as the base material, with a layer of gold placed over the U-channels in the cross-section of the fiber to create a surface plasmon resonance. There are three different sizes of internal fiber optic air hole diameters, with a larger channel circle below the u-channel for the formation of an energy leakage window. COMSOL software 6.0 assisted us in tuning the fiber optic structure and performance for the study, and the structural parameters analyzed mainly include the channel circle diameter, the channel circle spacing, the profundity measurement of the polished layer, and the nanoscale size variation of metal films. The results of the simulation study show that the optical fiber sensor achieves refractive index (RI) responsiveness across the 1.30 to 1.41 range, and in the RI interval of 1.40 to 1.41, the sensor exhibits the largest resonance peak shift, and its highest sensitivity reaches 10,200 nm/RIU, and the smallest full width at half peak (FWHM) corresponds to the RI of 1.34 with a value of 4.8 nm, and the highest figure of merit (FOM) corresponds to the RI of 1.34 with a value of 895.83 (1/RIU). COMSOL 6.0 simulation software, was used to simulate the changes in blood refractive index corresponding to different glucose concentrations, and the detection performance of the sensor for different concentrations of glucose was tested. Then, the results show that the glucose concentration in 75 mg/dL–175 mg/dL with RI detection sensitivity is 3750 nm/RIU, where the maximum refractive index sensitivity is 5455 nm/RIU. It shows that the sensor can be applied in the field of biomedical applications, with its convenience, fast response, and high sensitivity, it has great potential and development prospect in the market.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseBiosensing TechniquesBlood Glucose Self-MonitoringSurface Plasmon ResonanceFiber Optic TechnologyComputer SimulationSensitivity and SpecificityRefractometryHumans

Stichwörter der Autor:innen

biosensingglucose concentration detection in bloodsurface plasmon resonanceu-channel photonic crystal fiber

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Joint Laboratory for Extreme Conditions Matter Properties, The State Key Laboratory of Environment-Friendly Energy Materials, School of Mathematics and Science, Tianfu Institute of Research and Innovation, Southwest Uni…
  • School of Science, Lanzhou University of Technology, Lanzhou 730050, China.
  • Guangxi Key Laboratory of Precision Navigation Technology and Application, Guilin University of Electronic Technology, Guilin 541004, China.
  • School of Chemistry and Chemical Engineering, Jishou University, Jishou 416000, China.
  • College of Physics, Central South University, Changsha 410083, China.

ORCID-Profile: Tangyou Sun, Zao Yi

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhao, L., Yang, H., Sun, T., Song, Q., Yi, Z., & Yi, Y. (2025). Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood. Sensors. https://doi.org/10.3390/s25092647

Vancouver

Zhao L, Yang H, Sun T, Song Q, Yi Z, Yi Y. Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood. Sensors. 2025. doi:10.3390/s25092647

BibTeX
@article{Zhao2025,
  author = {Zhao, Lei and Yang, Hua and Sun, Tangyou and Song, Qianju and Yi, Zao and Yi, Yougen},
  title = {Model Design and Study of a U-Channel Photonic Crystal Fib Optic Sensor for Measuring Glucose Concentration in Blood},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25092647}
}
Kostenlos starten →