Novel Technique for In-Body Absorbed Power Density Assessment Based on Free-Space E -Field Measurement
IEEE Transactions on Microwave Theory and Techniques · 2024-07 · 72 (7) · 4127-4138
DOI: 10.1109/tmtt.2023.3336798 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Microwave Theory and Techniques, 2024-07. Verfasst von Massinissa Ziane und 4 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: French National Research Program for Environmental and Occupational Health of Agence Nationale de Sécurité Sanitaire de l’alimentation, de l’Environnement et d…, Labex CominLabs through EM-ART Project, “Région Bretagne”.
Abstract (Originalsprache)
We introduce a novel method for measurement of the absorbed power density (APD) above 6 GHz, accounting for antenna/body interaction. A reflectivity-based thin planar solid phantom is used to mimic the scattering characteristics of human skin. This allows to perturb the antenna under test (AUT) in a similar way as it would be perturbed by the presence of the human body. The lower electromagnetic losses in the phantom medium result in an enhanced transmission through the phantom facilitating free-space ${E}$ -field vector measurement on the opposite to the AUT side of the phantom. The measured ${E}$ -field is backpropagated in space to retrieve APD using a plane-wave spectrum (PWS) technique. The proposed method is validated at 60 GHz using reference antennas, namely, a cavity-fed dipole array and pyramidal horn with a slot array. A very good agreement is demonstrated between the target APD at the air/skin interface (peak, averaged, and spatial distribution) and the one reconstructed from the simulated and measured ${E}$ -field. The maximum relative deviations between the computed and measured peak ( $p\text {APD}$ ), 1 cm2 peak spatial average ( $ps\text {APD}_{1\,\text {cm}^{2}}$ ), and 4 cm2 peak spatial average ( $ps\text {APD}_{4\,\text {cm}^{2}}$ ) are 13.2% (0.55 dB), 14.9% (0.6 dB), and 15.7% (0.63 dB), respectively. The results demonstrate that the proposed technique is promising for experimental dosimetry and compliance testing of wireless devices operating above 6 GHz.
Förderung
- French National Research Program for Environmental and Occupational Health of Agence Nationale de Sécurité Sanitaire de l’alimentation, de l’Environnement et d…
- Labex CominLabs through EM-ART Project
- “Région Bretagne”
- French Ministry of Higher Education and Research
- Brittany Region, Ministry of Higher Education and Research, Rennes Métropole and Conseil Départemental through CPER Project SOPHIE/STIC and Ondes
- French National Center for Scientific Research
Zitieren
APA
Ziane, M., Boriskin, A., Leconte, C., Coq, L. L., & Zhadobov, M. (2024). Novel Technique for In-Body Absorbed Power Density Assessment Based on Free-Space E -Field Measurement. IEEE Transactions on Microwave Theory and Techniques, 72(7), 4127-4138. https://doi.org/10.1109/tmtt.2023.3336798
Vancouver
Ziane M, Boriskin A, Leconte C, Coq LL, Zhadobov M. Novel Technique for In-Body Absorbed Power Density Assessment Based on Free-Space E -Field Measurement. IEEE Transactions on Microwave Theory and Techniques. 2024;72(7):4127-4138. doi:10.1109/tmtt.2023.3336798
BibTeX
@article{Ziane2024,
author = {Ziane, Massinissa and Boriskin, Artem and Leconte, Cecile and Coq, Laurent Le and Zhadobov, Maxim},
title = {Novel Technique for In-Body Absorbed Power Density Assessment Based on Free-Space E -Field Measurement},
journal = {IEEE Transactions on Microwave Theory and Techniques},
year = {2024},
volume = {72},
number = {7},
pages = {4127--4138},
doi = {10.1109/tmtt.2023.3336798}
}