Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2026. Verfasst von Walter Simson und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media. We show that CMPE induced by heterogeneous acoustic velocity is a robust measure of phase aberration that can be used for acoustic autofocusing. CMPE is optimized iteratively using a differentiable beamforming approach to simultaneously improve the image focus while estimating the acoustic velocity field of the interrogated medium. The approach relies solely on wavefield measurements using a straight-ray integral solution of the two-way time-of-flight without explicit numerical time-stepping models of wave propagation. We demonstrate method performance through in silico simulations, in vitro phantom measurements, and in vivo mammalian models, showing practical applications in distributed aberration quantification, correction, and velocity estimation for medical ultrasound autofocusing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedPhantoms, ImagingUltrasonographyAnimalsAlgorithmsComputer SimulationMice

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Simson, W., Zhuang, L., Frey, B. N., Sanabria, S. J., Dahl, J. J., & Hyun, D. (2026). Ultrasound Autofocusing: Common Midpoint Phase Error Optimization via Differentiable Beamforming. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2025.3607875

Vancouver

Simson W, Zhuang L, Frey BN, Sanabria SJ, Dahl JJ, Hyun D. Ultrasound Autofocusing: Common Midpoint Phase Error Optimization via Differentiable Beamforming. IEEE Transactions on Medical Imaging. 2026. doi:10.1109/tmi.2025.3607875

BibTeX
@article{Simson2026,
  author = {Simson, Walter and Zhuang, Louise and Frey, Benjamin N and Sanabria, Sergio J and Dahl, Jeremy J and Hyun, Dongwoon},
  title = {Ultrasound Autofocusing: Common Midpoint Phase Error Optimization via Differentiable Beamforming},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2026},
  doi = {10.1109/tmi.2025.3607875}
}
Kostenlos starten →