EUVIMEDEUVIMED entdecken
Crossref

Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion Models for Sparse-View CT Reconstruction

Hanyu Chen, Zhixiu Hao, Lin Guo, Liying Xiao

IEEE Transactions on Medical Imaging · 2025-07 · 44 (7) · 3012-3024

DOI: 10.1109/tmi.2025.3557243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-07. Verfasst von Hanyu Chen und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sparse-view Computed Tomography (CT) image reconstruction is a promising approach to reduce radiation exposure, but it inevitably leads to image degradation. Although diffusion model-based approaches are computationally expensive and suffer from the training-sampling discrepancy, they provide a potential solution to the problem. This study introduces a novel Cascaded Diffusion with Discrepancy Mitigation (CDDM) framework, including the low-quality image generation in latent space and the high-quality image generation in pixel space which contains data consistency and discrepancy mitigation in a one-step reconstruction process. The cascaded framework minimizes computational costs by replacing some inference steps from pixel to latent space. The discrepancy mitigation technique addresses the training-sampling gap induced by data consistency, ensuring the data distribution is close to the original diffusion manifold. A specialized Alternating Direction Method of Multipliers (ADMM) is employed to process image gradients in separate directions, offering a more targeted approach to regularization. Experimental results across several datasets demonstrate CDDM's superior performance in high-quality image generation with clearer boundaries compared to existing methods, highlighting the framework's computational efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedImage Processing, Computer-AssistedHumansAlgorithmsPhantoms, Imaging

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Chen, H., Hao, Z., Guo, L., & Xiao, L. (2025). Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion Models for Sparse-View CT Reconstruction. IEEE Transactions on Medical Imaging, 44(7), 3012-3024. https://doi.org/10.1109/tmi.2025.3557243

Vancouver

Chen H, Hao Z, Guo L, Xiao L. Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion Models for Sparse-View CT Reconstruction. IEEE Transactions on Medical Imaging. 2025;44(7):3012-3024. doi:10.1109/tmi.2025.3557243

BibTeX
@article{Chen2025,
  author = {Chen, Hanyu and Hao, Zhixiu and Guo, Lin and Xiao, Liying},
  title = {Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion Models for Sparse-View CT Reconstruction},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2025},
  volume = {44},
  number = {7},
  pages = {3012--3024},
  doi = {10.1109/tmi.2025.3557243}
}
Kostenlos starten →